Search Legislation

Commission Regulation (EC) No 2075/2005 (repealed)Show full title

Commission Regulation (EC) No 2075/2005 of 5 December 2005 laying down specific rules on official controls for Trichinella in meat (Text with EEA relevance) (repealed)

 Help about what version

What Version

 Help about advanced features

Advanced Features

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Status:

Point in time view as at 05/12/2005.

Changes to legislation:

There are currently no known outstanding effects for the Commission Regulation (EC) No 2075/2005 (repealed), Division A.. Help about Changes to Legislation

Close

Changes to Legislation

Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

A.Mechanically assisted pooled sample digestion method/sedimentation techniqueU.K.

1.Apparatus and reagentsU.K.
(a)

Knife or scissors for cutting specimens

(b)

Trays marked off with 50 squares, each of which can hold samples of approximately 2 g of meat, or other tools giving equivalent guarantees as regards the traceability of the samples

(c)

Meat mincer or electrical blender

(d)

A stomacher lab-blender 3 500 thermo model

(e)

Plastic bags suitable for the stomacher lab-blender

(f)

Conical separation funnels, capacity 2 litres, preferably fitted with teflon safety plugs

(g)

Stands, rings and clamps

(h)

Sieves, mesh size 180 microns, external diameter 11 cm, with stainless steel or brash mesh

(i)

Funnels, internal diameter not less than 12 cm, to support the sieves

(j)

100 ml glass measuring cylinders

(k)

A thermometer accurate to 0,5 oC within the range 1 to 100 oC

(l)

A vibrator, e.g. an electric shaver with the head removed

(m)

A relay which will switch on and off at one-minute intervals

(n)

A trichinoscope with a horizontal table or a stereo-microscope, with a sub-stage transmitted light source of adjustable intensity

(o)

A larval counting basin and a number of 9 cm diameter petri dishes as in Chapter I(1)(l) and (m)

(p)

17,5 % hydrochloric acid

(q)

Pepsin, strength 1: 10 000 NF (US national formulary) corresponding to 1: 12 500 BP (British Pharmacopoeia) and to 2 000 FIP (Fédération internationale de pharmacie),

(r)

A number of 10 litre bins to be used for decontamination of apparatus, e.g. with formol, and for digestive juice remaining where specimens test positive

(s)

A balance accurate to 0,1 g.

2.Collecting of specimens and quantity to be digestedU.K.

As stipulated in Chapter I(2).

3.ProcedureU.K.
I.GrindingU.K.

Grinding the meat samples in a meat mincer beforehand will improve the digestion quality. If an electrical blender is used, the blender must be operated three to four times for approximately one second each time.

II.Digestion procedureU.K.

This procedure may involve complete pools (100 g of samples at a time) or pools of less than 100 g.

(a)

Complete pools (100 samples at a time)

(i)

The stomacher lab-blender 3 500 is fitted with a double plastic bag and the temperature control set at 40 to 41 oC.

(ii)

One and a half litres of water preheated to 40 to 41 oC is poured into the inner plastic bag.

(iii)

25 ml of 17,5 % hydrochloric acid is added to the water in the stomacher.

(iv)

100 samples weighing approximately 1 g each (at 25 to 30 oC) taken from each individual sample in accordance with 2 are added.

(v)

Lastly, 6 g pepsin is added. This order must be followed strictly to avoid decomposition of the pepsin.

(vi)

The stomacher is then allowed to pound the content of the bag for 25 minutes.

(vii)

The plastic bag is removed from the stomacher and the digestion fluid is filtered through the sieve into a 3 litre beaker.

(viii)

The plastic bag is washed with approximately 100 ml of water, which is then used to rinse the sieve and lastly added to the filtrate in the beaker.

(ix)

Up to 15 individual samples can be added to a total pool of 100 samples and examined together with these samples.

(b)

Smaller pools (less than 100 samples)

(i)

The stomacher lab-blender 3 500 is fitted with a double plastic bag and the temperature control set at 40 to 41 oC.

(ii)

A digestion fluid is prepared by mixing about one and a half litres of water and 25 ml of 17,5 % hydrochloric acid. 6 g of pepsin is added and the whole mixed at a temperature of 40 to 41 oC. This order must be followed strictly to avoid decomposition of the pepsin.

(iii)

Of the digestion fluid, a volume corresponding to 15 ml per gram of sample is measured (e.g. for 30 samples the volume required is 30 × 15 ml = 450 ml) and transferred to the inner of the two plastic bags, together with the meat samples weighing approximately 1 g (at 25 to 30 oC) taken from each individual sample in accordance with 2.

(iv)

Water at a temperature of approximately 41 oC is poured into the outer bag to make up a total volume in the two bags of one and a half litres. The stomacher is then allowed to pound the content of the bag for 25 minutes.

(v)

The plastic bag is removed from the stomacher and the digestion fluid is filtered through the sieve into a 3 litre beaker.

(vi)

The plastic bag is washed with approximately 100 ml of water (at 25 to 30 oC), which is then used to rinse the sieve and lastly added to the filtrate in the beaker.

III.Recovery of larvae by sedimentationU.K.
  • Ice (300 to 400 g of ice flakes, scaly ice or crushed ice) is added to the digestion fluid to bring its volume up to about 2 litres. The digestion fluid is then stirred until the ice has melted. In the case of smaller pools (see II(b)), the amount of ice must be reduced correspondingly.

  • The chilled digestion fluid is transferred to a 2 litre separation funnel, equipped with a vibrator in an extra clamp.

  • Sedimentation is allowed to proceed for 30 minutes, during which time the sedimentation funnel is vibrated intermittently, i.e. one minute vibration followed by a one-minute pause.

  • After 30 minutes, a 60 ml sample of the sediment is quickly run off into a 100 ml measuring cylinder (the funnel is rinsed with detergent solution after use).

  • The 60 ml sample is allowed to stand for at least 10 minutes, after which time the supernatant is withdrawn by suction to leave a volume of 15 ml, to be examined for presence of larvae.

  • For suction, a disposable syringe, equipped with a plastic tube, can be used. The length of the tube must be such that 15 ml remains in the measuring cylinder when the flanges of the syringe rest on the cylinder's rim.

  • The remaining 15 ml is poured into a larval counting basin or two petri dishes and examined using a trichinoscope or stereo-microscope.

  • The measuring cylinder is washed with 5 to 10 ml of tap water and the washings are added to the sample.

  • Digests are to be examined as soon as they are ready. Under no circumstances is examination to be postponed until the following day.

Where the digests are unclear or they are not examined within 30 minutes of their preparation, they must be clarified as follows:

  • the final sample of 60 ml is poured into a measuring cylinder and allowed to stand for 10 minutes; 45 ml of supernatant fluid is then removed by suction and the remaining 15 ml is made up to 45 ml with tap water,

  • after a further settling period of 10 minutes, 30 ml of supernatant fluid is removed by suction and the remaining 15 ml is poured into a petri dish or larval counting basin for examination,

  • the measuring cylinder is washed with 10 ml of tap water and these washings are added to the sample in the petri dish or the larval counting basin for examination.

IV.Positive or doubtful resultsU.K.

Where the result is positive or uncertain, the provisions laid down in Chapter I(3)(III) shall apply.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources