Melt the sample in an oven at approximately 45 °C.
Melt the sample in an oven at approximately 45 °C and filter a representative portion through a filter containing about 10 g of anhydrous sodium sulphate (4.3) in an environment shielded from strong natural and artificial light and maintained at 45 °C. Collect a suitable amount of butterfat.
Weigh, to the nearest 1 mg approximately 1 g of concentrated butter (or extracted butterfat (5.1.2)), (M). Transfer quantitatively to a 20 ml (V) volumetric flask using petroleum spirit (4.2), make up to the mark and mix thoroughly.
Transfer an aliquot to a 1 cm cell and measure the absorbance at 440 nm, against a petroleum spirit blank. Obtain the concentration of apo-carotenic ester in the solution by referring to the obtained standard curve (C μ/ml).
Pipette 0, 0,25, 0,5, 0,75 and 1,0 ml of apo-carotenic ester standard solution (4.1.2) into five 100 ml volumetric flasks. Dilute to volume with petroleum spirit (4.2) and mix.
The approximate concentrations of the solutions range from 0 to 2 μg/ml and are calculated accurately by reference to the concentration of the standard solution (4.1.2) (W × P) / 10 mg/ml. Measure the absorbances at 440 nm against a petroleum spirit (4.2) blank.
Plot the values of absorbance on the y axis against apo-carotenic ester concentration on the x axis. Calculate the equation of the standard curve.
The Whole Regulation you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: