ANNEX IU.K. ECODESIGN REQUIREMENTS

1.NO-LOAD POWER CONSUMPTION AND AVERAGE ACTIVE EFFICIENCYU.K.

(a) One year after this Regulation has come into force:U.K.

The no-load condition power consumption shall not exceed 0,50 W.

The average active efficiency shall be not less than:

(b) Two years after this Regulation has come into force:U.K.

2.MEASUREMENTSU.K.

The no-load condition power consumption and the average active efficiency referred to in point 1 shall be established by a reliable, accurate and reproducible measurement procedure, which takes into account the generally recognised state of the art.

[ F1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .]

3.INFORMATION TO BE PROVIDED BY MANUFACTURERSU.K.

For the purposes of conformity assessment pursuant to Article 4, the technical documentation shall contain the following elements:

Reported quantityDescription
Root mean square (Rms) output current (mA)Measured at load conditions 1-4
Rms output voltage (V)
Active output power (W)
Rms input voltage (V)Measured at load conditions 1-5
Rms input power (W)
Total harmonic distortion (THD)
True power factor
Power consumed (W)Calculated at load condition 1-4, measured at load condition 5
EfficiencyCalculated at load conditions 1-4
Average efficiencyArithmetic average of efficiency at load conditions 1-4

The relevant load conditions are as follows:

Percentage of nameplate output current
Load condition 1100 % ± 2 %
Load condition 275 % ± 2 %
Load condition 350 % ± 2 %
Load condition 425 % ± 2 %
Load condition 50 % (no-load condition)