Commission Regulation (EC) No 278/2009 of 6 April 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for no-load condition electric power consumption and average active efficiency of external power supplies (Text with EEA relevance) (repealed)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
This is the original version as it was originally adopted in the EU.
This legislation may since have been updated - see the latest available (revised) version
The no-load condition power consumption shall not exceed 0,50 W.
The average active efficiency shall be not less than:
0,500 · PO, for PO < 1,0 W;
0,090 · ln(PO) + 0,500, for 1,0 W ≤ PO ≤ 51,0 W;
0,850, for PO > 51,0 W.
The no-load condition power consumption shall not exceed the following limits:
AC-AC external power supplies, except low voltage external power supplies | AC-DC external power supplies except low voltage external power supplies | Low voltage external power supplies | |
---|---|---|---|
PO ≤ 51,0 W | 0,5 W | 0,3 W | 0,3 W |
PO > 51,0 W | 0,5 W | 0,5 W | n/a |
The average active efficiency shall be not less than the following limits:
AC-AC and AC-DC external power supplies, except low voltage external power supplies | Low voltage external power supplies | |
---|---|---|
PO ≤ 1,0 W | 0,480 · PO + 0,140 | 0,497 · PO + 0,067 |
1,0 W < PO ≤ 51,0 W | 0,063 · ln(PO) + 0,622 | 0,075 · ln(PO) + 0,561 |
PO > 51,0 W | 0,87 | 0,86 |
The no-load condition power consumption and the average active efficiency referred to in point 1 shall be established by a reliable, accurate and reproducible measurement procedure, which takes into account the generally recognised state of the art.
Measurements of power of 0,50 W or greater shall be made with an uncertainty of less than or equal to 2 % at the 95 % confidence level. Measurements of power of less than 0,50 W shall be made with an uncertainty of less than or equal to 0,01 W at the 95 % confidence level.
For the purposes of conformity assessment pursuant to Article 4, the technical documentation shall contain the following elements:
Reported quantity | Description |
---|---|
Root mean square (Rms) output current (mA) | Measured at load conditions 1-4 |
Rms output voltage (V) | |
Active output power (W) | |
Rms input voltage (V) | Measured at load conditions 1-5 |
Rms input power (W) | |
Total harmonic distortion (THD) | |
True power factor | |
Power consumed (W) | Calculated at load condition 1-4, measured at load condition 5 |
Efficiency | Calculated at load conditions 1-4 |
Average efficiency | Arithmetic average of efficiency at load conditions 1-4 |
The relevant load conditions are as follows:
Percentage of nameplate output current | |
---|---|
Load condition 1 | 100 % ± 2 % |
Load condition 2 | 75 % ± 2 % |
Load condition 3 | 50 % ± 2 % |
Load condition 4 | 25 % ± 2 % |
Load condition 5 | 0 % (no-load condition) |
When performing the market surveillance checks referred to in Article 3(2) of Directive 2005/32/EC, the authorities of the Member States shall apply the following verification procedure for the requirements set out in Annex I.
the result for no-load condition does not exceed the applicable limit value set out in Annex I by more than 0,10 W; and
the arithmetic average of efficiency at load conditions 1-4 as defined in Annex I does not fall below the applicable limit value for average active efficiency by more than 5 %.
the average of the results for no-load condition does not exceed the applicable limit value set out in Annex I by more than 0,10 W; and
the average of the arithmetic averages of efficiency at load conditions 1-4 as defined in Annex I does not fall below the applicable limit value for average active efficiency by more than 5 %.
The lowest available no-load condition power consumption of external power supplies can be approximated by:
0,1 W or less, for PO ≤ 90 W,
0,2 W or less, for 90 W < PO ≤ 150 W,
0,4 W or less, for 150 W < PO ≤ 180 W,
0,5 W or less, for PO > 180 W.
The best available active average efficiency of external power supplies according to most recent available data (status January 2008) can be approximated by:
0,090 · ln (PO) + 0,680, for 1,0 W ≤ PO ≤ 10,0 W,
0,890, for PO > 10,0 W.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: