Transmission system operators shall consult network users regarding procedures prior to their implementation and agree them with the regulatory authority.
on a website accessible to the public, free of charge and without any need to register or otherwise sign on with the transmission system operator;
on a regular/rolling basis; the frequency shall be according to the changes that take place and the duration of the service;
in a user-friendly manner;
in a clear, quantifiable, easily accessible way and on a non-discriminatory basis;
in downloadable format that allows for quantitative analyses;
in consistent units, in particular kWh (with a combustion reference temperature of 298,15 K) shall be the unit for energy content and m 3 (at 273,15 K and 1,01325 bar) shall be the unit for volume. The constant conversion factor to energy content shall be provided. In addition to the format above, publication in other units is also possible;
in the official language(s) of the Member State and in English.
Transmission system operators shall publish at least the following information about their systems and services:
a detailed and comprehensive description of the different services offered and their charges;
the different types of transportation contracts available for these services;
the network code and/or the standard conditions outlining the rights and responsibilities of all network users including:
harmonised transportation contracts and other relevant documents;
if relevant for access to the system, for all relevant points as defined in paragraph 3.2 of this Annex, a specification of relevant gas quality parameters, including at least the gross calorific value and the Wobbe index, and the liability or costs of conversion for network users in case gas is outside these specifications;
if relevant for access to the system, for all relevant points information on pressure requirements;
the procedure in the event of an interruption of interruptible capacity, including, where applicable, the timing, extent, and ranking of individual interruptions (for example pro-rata or first-come-last-interrupted);
the harmonised procedures applied when using the transmission system, including the definition of key terms;
provisions on capacity allocation, congestion management and anti-hoarding and reutilisation procedures;
the rules applicable for capacity trade on the secondary market vis-à-vis the transmission system operator;
rules on balancing and methodology for the calculation of imbalance charges;
if applicable, the flexibility and tolerance levels included in transportation and other services without separate charge, as well as any flexibility offered in addition to this and the corresponding charges;
a detailed description of the gas system of the transmission system operator and its relevant points of interconnection as defined in paragraph 3.2 of this Annex as well as the names of the operators of the interconnected systems or facilities;
the rules applicable for connection to the system operated by the transmission system operator;
information on emergency mechanisms, as far as it is the responsibility of the transmission system operator, such as measures that can lead to the disconnection of customers groups and other general liability rules that apply to the transmission system operator;
procedures agreed upon by transmission system operators at interconnection points, of relevance for access of network users to the transmission systems concerned, relating to interoperability of the network, agreed procedures on nomination and matching procedures and other agreed procedures that set out provisions in relation to gas flow allocations and balancing, including the methods used;
transmission system operators shall publish a detailed and comprehensive description of the methodology and process, including information on the parameters employed and the key assumptions, used to calculate the technical capacity.
all entry and exit points to and from a transmission network operated by a transmission system operator, with the exception of exit points connected to a single final customer, and with the exception of entry points linked directly to a production facility of a single producer that is located within the EU;
all entry and exit points connecting balancing zones of transmission system operators;
all points connecting the network of a transmission system operator with an LNG terminal, physical gas hubs, storage and production facilities, unless these production facilities are exempted under (a);
all points connecting the network of a given transmission system operator to infrastructure necessary for providing ancillary services as defined by Article 2(14) of Directive 2009/73/EC.
the technical capacity for flows in both directions;
the total contracted firm and interruptible capacity in both directions;
the nominations and re-nominations in both directions;
the available firm and interruptible capacity in both directions;
actual physical flows;
planned and actual interruption of interruptible capacity;
planned and unplanned interruptions to firm services as well as the information on restoration of the firm services (in particular, maintenance of the system and the likely duration of any interruption due to maintenance). Planned interruptions shall be published at least 42 days in advance.
interconnection point where the capacity is sold;
type of capacity, i.e. entry, exit, firm, interruptible;
quantity and duration of the capacity usage rights;
type of sale, e.g. transfer or assignment;
the total number of trades/transfers;
any other conditions known to the transmission system operator as mentioned in 3.3.
In so far such information is provided by a third party, transmission system operators shall be exempted from this provision.
a description of standardised products which can be sold on the secondary market;
lead time for the implementation/acceptation/registration of secondary trades. In case of delays the reasons have to be published;
the notification to the transmission system operator by the seller or the third party as referred to under 3.4(1) about name of seller and buyer and capacity specifications as outlined in 3.4(1).
In so far such information is provided by a third party, transmission system operators shall be exempted from this provision.
Textual Amendments
Regulation (EC) No 1775/2005 | This Regulation |
---|---|
Article 1 | Article 1 |
Article 2 | Article 2 |
— | Article 3 |
— | Article 4 |
— | Article 5 |
— | Article 6 |
— | Article 7 |
— | Article 8 |
— | Article 9 |
— | Article 10 |
— | Article 11 |
— | Article 12 |
Article 3 | Article 13 |
Article 4 | Article 14 |
— | Article 15 |
Article 5 | Article 16 |
— | Article 17 |
Article 6 | Article 18 |
— | Article 19 |
— | Article 20 |
Article 7 | Article 21 |
Article 8 | Article 22 |
Article 9 | Article 23 |
Article 10 | Article 24 |
Article 11 | Article 25 |
Article 12 | Article 26 |
Article 13 | Article 27 |
Article 14 | Article 28 |
Article 15 | Article 29 |
Article 16 | Article 30 |
— | Article 31 |
Article 17 | Article 32 |
Annex | Annex I |