ANNEX VII Measurements and calculations

1.For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements and calculations shall be made using harmonised standards the reference numbers of which have been published in the Official Journal of European Union, or other reliable, accurate and reproducible method, which takes into account the generally recognised state of the art methods, and whose results are deemed to be of low uncertainty.

2.The determination of the seasonal energy consumption and seasonal energy efficiency ratio (SEER) and seasonal coefficient of performance (SCOP) shall take into account:

(a)

European seasonal conditions, as defined in Table 1 of this Annex;

(b)

Reference design conditions, as defined in Table 3 of this Annex;

(c)

Electric energy consumption for all relevant modes of operation, using time periods as defined in Table 4 of this Annex;

(d)

Effects of the degradation of the energy efficiency caused by on/off cycling (if applicable) depending on the type of control of the cooling and/or heating capacity;

(e)

Corrections on the seasonal coefficients of performance in conditions where the heating load can not be met by the heating capacity;

(f)

The contribution of a back-up heater (if applicable) in the calculation of the seasonal efficiency of a unit in heating mode.

3.Where the information relating to a specific model, being a combination of indoor and outdoor unit(s), has been obtained by calculation on the basis of design, and/or extrapolation from other combinations, the documentation should include details of such calculations and/or extrapolations, and of tests undertaken to verify the accuracy of the calculations undertaken (including details of the mathematical model for calculating performance of such combinations, and of measurements taken to verify this model).

4.The energy efficiency ratio (EERrated) and, when applicable, coefficient of performance (COPrated) for double ducts and single ducts shall be established at the standard rating conditions as defined in Table 2 of this Annex.

5.The calculation of electricity consumption for cooling and/or heating shall take into account electric energy consumption of all relevant modes of operation, when appropriate, using time periods as defined in Table 4 of this Annex.

Table 1

Bin number (j), outdoor temperature (Tj) in °C and number of hours per bin (hj) for the cooling season and for heating seasons ‘average’, ‘warmer’ and ‘colder’. ‘db’ = dry bulb temperature

COOLING SEASONHEATING SEASON
AverageWarmerColder
j#Tj°Chjhj#Tj°ChjAhhj WhhjCh
dbdb
1172051 to 8– 30 to – 23000
2182279-22001
31922510-21006
42022511-200013
52121612-190017
62221513-180019
72321814-170026
82419715-160039
92517816-150041
102615817-140035
112713718-130052
122810919-120037
13298820-110041
14306321-101043
15313922-925054
16323123-823090
17332424-7240125
18341725-6270169
19351326-5680195
2036927-4910278
2137428-3890306
2238329-21650454
2339130-11730385
244003102400490
3212800533
3323203380
34335722228
35435663261
36530363279
376330175229
387326162269
398348259233
409335360230
4110315428243
4211215430191
4312169503146
4413151444150
451410538497
46157429461
Total2 6024 9103 5906 446

Table 2

Standard rating conditions, temperatures in ‘dry bulb’ air temperature (‘wet bulb’ indicated in brackets)

a

In case of single ducts, the condensor (evaporator) when cooling (heating), is not supplied with outdoor air, but indoor air.

ApplianceFunctionIndoor air temperature(°C)Outdoor air temperature(°C)
air conditioners, excluding single ductcooling27 (19)35 (24)
heating20 (max. 15)7(6)
single ductcooling35 (24)35 (24)a
heating20 (12)20 (12)a

Table 3

Reference design conditions, temperatures in ‘dry bulb’ air temperature (‘wet bulb’ indicated in brackets)

Function / seasonIndoor air temperature(°C)Outdoor air temperature(°C)Bivalent temperature(°C)Operating limit temperature(°C)
TinTdesignc/TdesignhTbivTol
cooling27 (19)Tdesignc = 35 (24)n.a.n.a.
heating / Average20 (15)Tdesignh = – 10 (– 11)max. 2max. – 7
heating / WarmerTdesignh = 2 (1)max. 7max. 2
heating / ColderTdesignh = – 22 (– 23)max. – 7max. – 15

Table 4

Operational hours per type of appliance per functional mode to be used for calculation of electricity consumption

Type of appliance / functionality (if applicable)UnitHeating seasonOn modeThermostat-off modeStandby modeOff modeCrankcase heater mode
cooling: HCEheating: HHEHTOHSBHOFFHCK
Air conditioners, except double ducts and single duct
Cooling mode, if appliance offers cooling onlyh/annum3502212 1425 0887 760
Cooling and heating modes, if appliance offers both modesCooling modeh/annum3502212 14202 672
Heating modeh/annumAverage1 40017900179
Warmer1 40075500755
Colder2 10013100131
Heating mode, if appliance offers heating onlyh/annumAverage1 40017903 6723 851
Warmer1 40075504 3454 476
Colder2 10013102 1892 944
Double duct air conditionercooling: HCEheating: HHEHTOHSBHOFFHCK
Cooling mode, if appliance offers cooling onlyh/60 min1n/an/an/an/a
Cooling and heating modes, if appliance offers both modesCooling modeh/60 min1n/an/an/an/a
Heating modeh/60 min1n/an/an/an/a
Heating mode, if appliance offers heating onlyh/60 min1n/an/an/an/a
Single duct air conditionercooling: HCEheating: HHE
Cooling modeh/60 min1n/an/an/an/a
Heating modeh/60 min1n/an/an/an/a