xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"

ANNEX IIU.K.Method for the calculation of the rate of recycled lead content

1.The rate of recycled lead content is calculated as follows:U.K.

, [mass %]

where:

RPb

=

calculated rate of recycled lead (Pb) from a recycling process for the purpose of Article 12(4) of Directive 2006/66/EC [in mass %];

mPb output

=

the mass of Pb in output fractions accounting for recycling is the share of Pb contained in these fractions which results from the recycling of lead-acid batteries and accumulators per calendar year [in tonnes];

mPb input

=

the mass of Pb in the input fraction entering the battery recycling process is defined as the yearly average Pb content of waste lead-acid batteries and accumulators multiplied by the input mass of lead-acid batteries and accumulators per calendar year [in tonnes].

2.In the output fraction the lead (Pb) contained in slag at the end of the recycling process is not accounted for the rate of recycled lead content.U.K.

[F13.For the purposes of point 1, Directive 2006/66/EC is to be read as if “waste battery or accumulator” had the meaning given by Article 2(1)(4A).]U.K.