Commission Regulation (EU) No 601/2012 (repealed)Show full title

Commission Regulation (EU) No 601/2012 of 21 June 2012 on the monitoring and reporting of greenhouse gas emissions pursuant to Directive 2003/87/EC of the European Parliament and of the Council (Text with EEA relevance) (repealed)

21. Determination of greenhouse gas emissions from CO2 capture activities for the purposes of transport and geological storage in a storage site permitted under Directive 2009/31/EC U.K.

A. Scope U.K.

CO2 capture shall be performed either by a dedicated installation receiving CO2 by transfer from one or more other installations, or by the same installation carrying out the activities producing the captured CO2 under the same greenhouse gas emissions permit. All parts of the installation related to CO2 capture, intermediate storage, transfer to a CO2 transport network or to a site for geological storage of CO2 greenhouse gas emissions shall be included in the greenhouse gas emissions permit and accounted for in the associated monitoring plan. In the case of the installation carrying out other activities covered by Directive 2003/87/EC, the emissions of those activities shall be monitored in accordance with the other relevant sections of this Annex.

The operator of a CO2 capture activity shall at least include the following potential sources of CO2 emission:

(a)

CO2 transferred to the capture installation;

(b)

combustion and other associated activities at the installation that are related to the capture activity, including fuel and input material use.

B. Quantification of transferred and emitted CO2 amounts U.K.

B.1.Installation level quantificationU.K.

Each operator shall calculate the emissions by taking into account the potential CO2 emissions from all emission relevant processes at the installation, as well as the amount of CO2 captured and transferred to the transport network, using the following formula:

Ecapture installation = Tinput + Ewithout capture – Tfor storage

Where:

Ecapture installation

=

Total greenhouse gas emissions of the capture installation;

Tinput

=

Amount of CO2 transferred to the capture installation, determined in accordance with Article 40 to 46 and Article 49.

Ewithout capture

=

Emissions of the installation assuming the CO2 were not captured, meaning the sum of the emissions from all other activities at the installation, monitored in accordance with relevant sections of Annex IV;

Tfor storage

=

Amount of CO2 transferred to a transport network or a storage site, determined in accordance with Article 40 to 46 and Article 49.

In cases where CO2 capture is carried out by the same installation as the one from which the captured CO2 originates, the operator shall use zero for Tinput.

In cases of stand-alone capture installations, the operator shall consider Ewithout capture to represent the amount of emissions that occur from other sources than the CO2 transferred to the installation for capture. The operator shall determine those emissions in accordance with this Regulation.

In the case of stand-alone capture installations, the operator of the installation transferring CO2 to the capture installation shall deduct the amount Tinput from the emissions of its installation in accordance with Article 49.

B.2.Determination of transferred CO2 U.K.

Each operator shall determine the amount of CO2 transferred from and to the capture installation in accordance with Article 49 by means of measurement methodologies carried out in accordance with Articles 40 to 46.

Only where the operator of the installation transferring CO2 to the capture installation demonstrates to the satisfaction of the competent authority that CO2 transferred to the capture installation is transferred in total and to at least equivalent accuracy, may the competent authority allow that operator to use a calculation-based methodology in accordance with Article 24 or 25 to determine the amount Tinput instead of a measurement-based methodology in accordance with Article 40 to 46 and Article 49.