ANNEXGENERAL EXPLANATIONS

Unless otherwise stated in the reporting sections of this Annex, the reported data shall cover the activities of the undertaking during the calendar year for which the report is submitted.

The units of measurement, the gases covered, the level of detail and an indication of the year in which activities are to be reported for the first time are specified separately in each reporting section.

The general format of the reporting tool is set out in the following reporting sections. The numbering of the sections presented below has no relevance with the numbering of Regulation (EU) No 517/2014 or the electronic reporting tool, but is used in the formulas for the automatic calculation of certain values.

Reporting sections

Section 1:To be filled in by producers of gases — Article 19(1) and (2) of Regulation (EU) No 517/2014 and point 1(a) and (c) of Annex vii to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2014 (by 31 March 2015 at the latest).

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each gas listed in Annex I or Annex II of Regulation (EU) No 517/2014. Quantities of mixtures containing those substances placed on the market shall be reported, also indicating the amounts used as components of these mixtures from other sources than own production.

F2INFORMATION TO BE REPORTED

COMMENTS

1A

Total quantity of production from facilities in the Union

1Aa

thereof: Amounts not captured

1A_a

thereof: Amounts destroyed

If the in-line destruction is carried out by another undertaking, the latter should be specified

Reports from producers which carry out destruction on the total quantities destroyed shall be made in reporting Section 8

AUTOMATICALLY CALCULATED QUANTITIES

1Ab

thereof: Total amount generated and captured

1Ab = 1A - 1Aa

INFORMATION TO BE REPORTED

1B

thereof: Quantity of production from facilities in the Union consisting of recovered by-production or unwanted products where that by-production or those products have been destroyed in the facilities prior to the placing on the market

Reports from producers which carry out destruction on the total quantities destroyed shall be made in reporting Section 8

1C

thereof: Quantity of production from facilities in the Union consisting of recovered by-production or unwanted products where that by-production or those products have been handed over to other undertakings for destruction and had not been placed on the market previously

The undertaking carrying out the destruction shall be identified

1C_a

thereof: Amounts of hydrofluorocarbons produced for feedstock uses within the Union

The Member State where feedstock use will take place shall be indicated

1C_a1

thereof: Without prior capture

Only to be reported for HFC-23

AUTOMATICALLY CALCULATED QUANTITIES

1C_a2

thereof: After prior capture

1C_a2 = 1C_a – 1C_a1;

To be calculated only for HFC-23

INFORMATION TO BE REPORTED

1C_b

thereof: Amount of hydrofluorocarbons produced for uses within the Union exempted under the Montreal Protocol

The type of exempted use shall be specified

AUTOMATICALLY CALCULATED QUANTITIES

1D

thereof: Total quantity of own production captured and destroyed which has not been placed on the market previously

1D = 1B + 1C

1E

Production available for sale or feedstock use

1E = 1A – 1D – 1A_a

Section 2:To be filled in by importers of gases — Article 19(1) of Regulation (EU) No 517/2014 and point 2(a) of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2014 (by 31 March 2015 at the latest).

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each gas listed in Annex I or Annex II to Regulation (EU) No 517/2014, for mixtures containing at least one of those gases or for each gas or mixture contained in imported pre-blended polyols. F3For the first time for the reporting on activities in 2019, quantities of hydrofluorocarbons shall be reported separately for each country of origin, except where indicated otherwise in the table below.

Only bulk imports shall be reported here, including quantities shipped alongside equipment for the purpose of charging that equipment after import, but not quantities contained in equipment. Imports of gases contained in products or equipment shall be reported in reporting section 11. All imports shall be reported, except imports for transit through the Unions customs territory or imports under other procedures that allow for a temporary movement of the goods on the customs territory provided that in the latter case the goods remain no longer than 45 days on the customs territory.

F1INFORMATION TO BE REPORTED

COMMENTS

2A

Amount imported into the Union

2B

Amount imported into the Union by the reporting undertaking, not released for free circulation, and re-exported contained in products or equipment by the reporting undertaking

Reporting of hydrofluorocarbons by country of origin is not necessary.

Bulk gases imported for inward processing, charged into products or equipment and subsequently re-exported.

Where the re-export in products or equipment (Section 2B) does not take place in the same calendar year as the import, the quantities reported in Section 2B may include re-exports in products or equipment of 1 January stocks not placed on the Union market as reported in Section 4C

Bulk gas exports shall only be reported in Section 3

2C

Amount of used, recycled or reclaimed hydrofluorocarbons

2D

Amount of virgin hydrofluorocarbons imported for feedstock use

2E

Amount of virgin hydrofluorocarbons imported for uses exempted under the Montreal Protocol

The type of exempted use shall be specified

F4

2F

Amount of hydrofluorocarbons contained in pre-blended polyols

Section 3:To be filled in by exporters of gases — Article 19(1) and (2) of Regulation (EU) No 517/2014 and point 3(a) and (b) of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2014 (by 31 March 2015 at the latest).

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each gas listed in Annex I or Annex II to Regulation (EU) No 517/2014, for mixtures containing at least one of those gases or for each gas or mixture contained in exported pre-blended polyols. F3For the first time for the reporting on activities in 2019, quantities of hydrofluorocarbons shall be reported separately for each country of destination, except where indicated otherwise in the table below.

Only exports of bulk gases, including any quantities shipped alongside equipment for the purpose of charging that equipment after export, shall be reported under this Section.

Quantities from own production or own import supplied to other undertakings in the Union for direct export shall be reported in reporting Section 5.

F1INFORMATION TO BE REPORTED

COMMENTS

3A

Total amount exported from the Union

3B

Exported amounts from own production or import

Reporting by country of destination is not necessary

AUTOMATICALLY CALCULATED QUANTITIES

3C

Exported amount purchased from other undertakings within the Union

3C = 3A – 3B

INFORMATION TO BE REPORTED

3D

Amount exported for recycling

Reporting by country of destination is not necessary

3E

Amount exported for reclamation

Reporting by country of destination is not necessary

3F

Amount exported for destruction

Reporting by country of destination is not necessary

3G

Amount of used, recycled or reclaimed hydrofluorocarbons exported

3H

Amount of virgin hydrofluorocarbons exported for feedstock use

3I

Amount of virgin hydrofluorocarbons exported for uses exempted under the Montreal Protocol

The type of exempted use shall be specified

F4

3J

Amount of hydrofluorocarbons contained in pre-blended polyols

Section 4:To be filled in by producers and importers of gases — Article 19(1) of Regulation (EU) No 517/2014 and points 1(d), 2(b) and 2(d) of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2014 (by 31 March 2015 at the latest).

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each gas listed in Annex I or Annex II to Regulation (EU) No 517/2014 or for mixtures containing at least one of those gases or for each gas or mixture contained in pre-blended polyols.

INFORMATION TO BE REPORTED

COMMENTS

4A

Total 1st January stocks

4B

thereof: 1 January stocks of quantities from own import or production

4C

thereof: 1 January stocks of quantities from own import or production, previously not placed on the market

In particular unsold own production and own imports not released for free circulation

AUTOMATICALLY CALCULATED QUANTITIES

4D

thereof: 1 January stocks of quantities from own import or production, previously placed on the market

In particular own imports released for free circulation

4D = 4B – 4C

4E

Other 1 January stocks

In particular from purchases within the Union

4E = 4A – 4B

INFORMATION TO BE REPORTED

4F

Total 31st December stocks

4G

thereof: 31 December stocks of quantities from own import or production

4H

thereof: 31 December stocks of quantities from own import or production, previously not placed on the market

In particular unsold own production, own imports not released for free circulation

AUTOMATICALLY CALCULATED QUANTITIES

4I

thereof: 31 December stocks of quantities from own import or production, previously placed on the market

In particular own import released for free circulation

4I = 4G – 4H

4J

thereof: Other 31 December stocks

In particular from purchases within the Union

4J = 4F-4G

INFORMATION TO BE REPORTED

4K

Amount reclaimed by the undertaking itself

4L

Amount recycled by the undertaking itself

AUTOMATICALLY CALCULATED QUANTITIES

F14M

Total amount physically placed on the market

4M = 1E + 2A – 2B – 3B + 4C – 4H

Section 5:Quantities for uses exempted under Article 15(2), to be filled in by producers and importers of hydrofluorocarbons — Article 19(1), (2) (3) and (4) of Regulation (EU) No 517/2014 and points 1(b) and 2(a) of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2014 (by 31 March 2015 at the latest).

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each hydrofluorocarbon (for gases listed in Section 1 of Annex I to Regulation (EU) No 517/2014, for mixtures or pre-blended polyols containing at least one of those gases).

INFORMATION TO BE REPORTED

COMMENTS

5A

Quantity imported into the Union for destruction

The undertaking/s carrying out the destruction shall be specified.

Reports from importers which also carry out destruction themselves on the quantities destroyed shall be made in reporting Section 8.

5B

Quantity used by a producer or importer in feedstock applications or supplied directly by a producer or an importer to undertakings for use in feedstock applications

The feedstock using undertaking/s shall be specified

Reports from producers or importers which are also feedstock users themselves on their feedstock use shall be made in reporting section 7.

5C

Quantity supplied directly to undertakings for export out of the Union, where those quantities were not subsequently made available to another party within the Union prior to export

On a voluntary basis, quantities supplied directly to undertakings for manufacturing of equipment in the Union, where such equipment is subsequently directly exported out of the Union

The exporting undertaking/s shall be specified. Verification documents should be provided.

Only hydrofluorocarbons in bulk shall be reported, not quantities contained in products or equipment.

Data on supply for the manufacturing of equipment that is directly exported may be provided for information purposes, and should specify the exporting equipment manufacturer and quantities that were exported.

5D

Quantity supplied directly for use in military equipment

The undertaking receiving the quantity for use in military equipment shall be specified.

5E

Quantity supplied directly to an undertaking using it for the etching of semiconductor material or the cleaning of chemicals vapour deposition chambers within the semiconductor manufacturing sector

The receiving semiconductor manufacturer shall be specified.

5F

Quantity supplied directly to an undertaking producing metered dose inhalers for the delivery of pharmaceutical ingredients

The receiving producer of metered dose inhalers for the delivery of pharmaceutical ingredients shall be specified.

Section 6:Categories of application of gases for the EU market, to be filled in by producers and importers of gases — Article 19(1) and (2) of Regulation (EU) No 517/2014 and points 1(a), and 2(a) of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2014 (by 31 March 2015 at the latest).

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each gas listed in Annex I or Annex II to Regulation (EU) No 517/2014 or mixture containing at least one of those gases.

INFORMATION TO BE REPORTED

COMMENTS

6A

Export

For hydrofluorocarbons, the amount reported here [6A] shall be the same amount or higher as that reported in reporting section 5 as supplied directly to undertakings for export out of the Union, where those quantities were not subsequently made available to any other party within the Union, prior to export [5C].

6B

Destruction

For hydrofluorocarbons, the amount reported here [6B] shall be the same amount or higher as that reported in reporting section 5 as imported into the Union for destruction [5A].

6C

Military equipment

For hydrofluorocarbons, the amount reported here [6C] shall be the same amount or higher as that reported in reporting section 5 as supplied directly for use in military equipment [5D].

6D

Refrigeration, air-conditioning and heating

6E

Other heat transfer fluids

6F

Production of foams

6G

Production of pre-blended polyols

6H

Fire protection

6I

Aerosols — medical dose inhalers

For hydrofluorocarbons, the amount reported here [6I] shall be the same amount or higher as that reported in reporting section 5 as supplied directly to an undertaking producing metered dose inhalers for the delivery of pharmaceutical ingredients [5F].

6J

Aerosols — other uses

6K

Solvents

6L

Feedstock

For hydrofluorocarbons, the amount reported here [6L] shall be the same amount or higher as that reported in reporting section 5 as used by a producer in feedstock applications or supplied directly by a producer or an importer to undertakings for use in feedstock applications [5B].

6M

Semiconductor manufacture

For hydrofluorocarbons, the amount reported here [6M] shall be the same amount or higher as that reported in reporting section 5 as supplied directly to an undertaking using it for the etching of semiconductor material or the cleaning of chemicals vapour deposition chambers within the semiconductor manufacturing sector [5E].

6N

Photovoltaics manufacture

6O

Other electronics manufacture

6P

Electrical switchgear equipment

6Q

Particle accelerators

6R

Magnesium die casting operations

6S

Anaesthetics

6T

Other or unknown application

Other application/s shall be specified, and unknown application shall be explained by the reporter.

6U

Leakage during storage, transport or transfer

6V

Accountancy adjustments

Where such quantities are reported, an explanation should be provided

AUTOMATICALLY GENERATED CALCULATIONS OF QUANTITIES

6W

Total quantities for the categories for applications

6W = 6A + 6B + 6C + 6D + 6E + 6F + 6G + 6H + 6I + 6J + 6K + 6L + 6M + 6N + 6O + 6P + 6Q + 6R + 6S + 6T + 6U + 6V

If data are reported correctly, then the total quantities for the categories of applications [6W] will correspond to the calculated total quantity supplied to the Union market [6X].

6X

Total quantity supplied to the Union market

6X = 1E + 2A – 3B + 4B – 4G + 4K

Section 7:To be filled in by feedstock users of gases — Article 19(3) of Regulation (EU) No 517/2014 and point 5 of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2014 (by 31 March 2015 at the latest).

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each gas listed in Annex I or Annex II to Regulation (EU) No 517/2014 or mixture containing at least one of those gases.

Only quantities actually used as feedstock shall be reported here.

Where hydrofluorocarbons (gases listed in Section 1 of Annex I to Regulation (EU) No 517/2014 or mixture containing at least one of those gases) were produced or imported by the undertaking using them as the feedstock, the quantities used shall be reported in section 5 as well. Where the undertaking produced or imported those gases and subsequently sold them for use as feedstock to other undertakings, the quantities supplied shall only be reported in reporting section 5, specifying the feedstock using undertaking.

INFORMATION TO BE REPORTED

COMMENTS

7A

Amount used as feedstock by the undertaking itself

Section 8:To be filled in by undertakings having destroyed gases — Article 19(2) of Regulation (EU) No 517/2014 and point 4 of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2014 (by 31 March 2015 at the latest).

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each fluorinated greenhouse gas listed in Annex I or Annex II to Regulation (EU) No 517/2014 or mixture containing at least one of those gases.

The total quantities destroyed by the reporting undertaking themselves are to be reported. Undertakings which are producers shall also report on the quantities of its own production which have been destroyed, in reporting section 1.

Undertakings which are importers of hydrofluorocarbons (gases listed in Section 1 of Annex I to Regulation (EU) No 517/2014 or mixture containing at least one of those gases) shall report the quantities of its imports which have been destroyed, in reporting section 5.

Quantities sent for destruction to other undertakings in the EU shall not be reported here. Quantities exported for destruction outside the EU shall be reported in 3F.

INFORMATION TO BE REPORTED

COMMENTS

8A

Amount destroyed by the reporting company using high temperature combustion

8B

Amount destroyed by the reporting company using thermal desorption

8C

Amount destroyed by the reporting company using other technologies

The employed destruction technologies shall be specified

AUTOMATICALLY CALCULATED QUANTITIES

8D

Total amount destroyed by the undertaking itself

8D = 8A + 8B + 8C

INFORMATION TO BE REPORTED

8E

1 January stocks waiting to be destroyed

8F

31 December stocks intended for destruction waiting to be destroyed

Section 9:To be filled in by producers or importers having authorised the use of a hydrofluorocarbon quota to undertakings placing on the market refrigeration, air conditioning and heat pump equipment charged with hydrofluorocarbons — Article 19(1) of Regulation (EU) No 517/2014 and points 1(e) and 2(c) of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities in 2015 (by 31 March 2016 at the latest).

Quantities shall be reported in tonnes of CO2 equivalents with accuracy to 1 tonne of CO2 equivalent, without distinction between different hydrofluorocarbons.

Only authorisations issued during the calendar year for which the report is submitted shall be reported.

INFORMATION TO BE REPORTED

COMMENTS

9A

Quantities subject to authorisations to use a quota given to producers or importers of pre-charged equipment under Article 18(2) of Regulation (EU) No 517/2014

The undertaking receiving the authorisation shall be specified.

Section 10:To be filled in by undertakings which have received their quota exclusively on the basis of a declaration pursuant to Article 16(2) of Regulation (EU) No 517/2014 and which have authorised the use of a hydrofluorocarbon quota to undertakings placing on the market refrigeration, air conditioning and heat pump equipment charged with hydrofluorocarbons pursuant to second subparagraph of Article 18(2) of Regulation (EU) No 517/2014 — Article 19(1) of Regulation (EU) No 517/2014 and points 1(e) and 2(c) of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities in 2015 (by 31 March 2016 at the latest).

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each hydrofluorocarbon (gases listed in Section 1 of Annex I to Regulation (EU) No 517/2014 or mixture containing at least one of those gases).

All hydrofluorocarbon supplies linked to the authorisations issued during the calendar year for which the report is submitted, as reported under section 9, shall be reported in this reporting section. This information is needed to verify compliance with Article 18(2) of Regulation (EU) No 517/2014.

INFORMATION TO BE REPORTED

COMMENTS

10A

Amount of gas supplied to undertakings, to which authorisations were issued for the placing on the market refrigeration, air conditioning and heat pump equipment charged with hydrofluorocarbons.

The receiving undertaking/s shall be specified.

With the report, undertakings should submit additional proof for all physical supplies reported here (e.g. invoices).

Section 11:To be filled in by undertakings having placed on the market gases contained in products or equipment pursuant to Article 19(4) of Regulation 517/2014 — Article 19(4) of Regulation (EU) No 517/2014 and point 6 of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2014 (by 31 March 2015 at the latest).

Quantities of fluorinated greenhouse gases listed in Annex I or Annex II to Regulation (EU) No 517/2014 or mixtures containing at least one of those gases contained in the products and equipment shall be reported in metric tonnes with accuracy to the third decimal place, by category. In addition to the total quantity of gases, the number of units shall be reported per category, unless otherwise stated.

Producers of products or equipment manufactured in the Union shall not report on products and equipment where the contained gases were previously imported into or produced in the Union. Where a producer itself produces bulk gas in the Union for use in the Union for manufacturing their products and equipment, its reporting on production (reporting section 1) would similarly cover the relevant gas amounts, so these amounts shall also not be reported in this section.

Importers of products or equipment containing a fluorinated greenhouse gas listed in Annex I or II to Regulation (EU) No 517/2014 shall report on all gas containing imports released by customs for free circulation in the Union. Imports of pre-blended polyols are not to be reported in this section but in section 2. Where hydrofluorocarbons (gases listed in Section 1 of Annex I to Regulation (EU) No 517/2014 or mixture containing at least one of those gases) contained in imported refrigeration, air conditioning or heat pump equipment had previously been exported from the Union, and had been subject to the hydrofluorocarbon quota limitation for placing on the market, that shall be reported in reporting section 12 in order to prove compliance with Article 14 of Regulation (EU) No 517/2014.

The categories of products or equipment listed below include components intended for the specified product or equipment categories.

The term ‘direct design’ refers in particular to air-to-air, water-to-air, brine-to-air systems; the term ‘indirect design’ in particular to air-to-water, water-to-water, brine-to-water systems, including hydronic heat-pumps.

AUTOMATICALLY CALCULATED QUANTITIES

COMMENTS

11A

Stationary equipment for comfort cooling or heating

11A = 11A1 + 11A2 + 11A3 + 11A4 + 11A5 + 11A6 + 11A7 + 11A8 + 11A9 + 11A10 + 11A11 + 11A12 + 11A13 + 11A14

INFORMATION TO BE REPORTED

11A1

Stationary equipment for comfort cooling/heating, direct design: Standalone/monobloc units of moveable type

11A2

Stationary equipment for comfort cooling/heating, direct design: standalone/monobloc units of rooftop type

11A3

Stationary equipment for comfort cooling/heating, direct design: standalone/monobloc units of other type

The equipment type/s shall be specified.

11A4

Stationary equipment for comfort cooling/heating, direct design: single split units charged with 3 kilograms or more of refrigerant

11A5

Stationary equipment for comfort cooling/heating, direct design: single split units charged with less than 3 kilograms of refrigerant

11A6

Stationary equipment for comfort cooling/heating, direct design: multi split units

11A7

Stationary equipment for comfort cooling/heating, indirect design: standalone/monobloc units for domestic use

11A8

Stationary equipment for comfort cooling/heating, indirect design: standalone/monobloc units for commercial or industrial use

11A9

Stationary equipment for comfort cooling/heating, indirect design: standalone/monobloc units for other use

The intended use/s shall be specified.

11A10

Stationary equipment for comfort cooling/heating, indirect design: split units for domestic use

11A11

Stationary equipment for comfort cooling/heating, indirect design: split units for commercial or industrial use

11A12

Stationary equipment for comfort cooling/heating, indirect design: split units for other use

The intended use/s shall be specified.

11A13

Stationary equipment for comfort cooling/heating, both direct and indirect: standalone/monobloc units

11A14

Stationary equipment for comfort cooling/heating, both direct and indirect: split units

AUTOMATICALLY CALCULATED QUANTITIES

11B

Stationary equipment for refrigeration

11B = 11B1 + 11B2 + 11B3 + 11B4 + 11B5 + 11B6 + 11B7 + 11B8 + 11B9 + 11B10 + 11B11 + 11B12 + 11B13 + 11B14

INFORMATION TO BE REPORTED

11B1

Stationary equipment for refrigeration, direct design: standalone/monobloc units for domestic use

11B2

Stationary equipment for refrigeration, direct design: standalone/monobloc units for commercial or industrial use

11B3

Stationary equipment for refrigeration, direct design: standalone/monobloc units for other use

The intended use/s shall be specified.

11B4

Stationary equipment for refrigeration, direct design: split units for commercial or industrial use

11B5

Stationary equipment for refrigeration, direct design: split units for other use

The intended use/s shall be specified.

11B6

Stationary equipment for refrigeration, indirect design: standalone/monobloc units for commercial or industrial use

11B7

Stationary equipment for refrigeration, indirect design: standalone/monobloc units for other use

The intended use/s shall be specified.

11B8

Stationary equipment for refrigeration, indirect design: split units for commercial or industrial use

11B9

Stationary equipment for refrigeration in indirect design: split units for other use

The intended use/s shall be specified.

11B10

Stationary equipment for refrigeration, both direct and indirect: standalone/monobloc units

11B11

Stationary equipment for refrigeration, both direct and indirect: split units

11B12

Stationary equipment for process cooling or heating in direct design

11B13

Stationary equipment for process cooling or heating in indirect design

11B14

Stationary equipment for process cooling or heating, both direct and indirect

11C

Heat pump tumble dryers

AUTOMATICALLY CALCULATED QUANTITIES

11D

Stationary heating/air conditioning including heatpumps as well as refrigeration (HACR) equipment for any other purposes

11D = 11D1 + 11D2 + 11D3

INFORMATION TO BE REPORTED

11D1

Stationary HACR equipment for any other purposes, direct design

The equipment type/s and purpose/s shall be specified.

11D2

Stationary HACR equipment for any other purposes, indirect design

The equipment type/s and purpose/s shall be specified.

11D3

Stationary HACR equipment for any other purposes, both direct and indirect

The equipment type/s and purpose/s shall be specified.

AUTOMATICALLY CALCULATED QUANTITIES

11E

Mobile refrigeration equipment

11E = 11E1 + 11E2 + 11E3 + 11E4

INFORMATION TO BE REPORTED

11E1

Mobile refrigeration equipment for refrigerated light duty vehicles (e.g. vans)

11E2

Mobile refrigeration equipment for refrigerated heavy duty vehicles (including trucks and trailers)

11E3

Mobile refrigeration equipment for refrigerated ships

11E4

Any other mobile refrigeration equipment

The equipment type/s shall be specified.

AUTOMATICALLY CALCULATED QUANTITIES

11F

Mobile air conditioning equipment

11F = 11F1 + 11F2 + 11F3 + 11F4 + 11F5 + 11F6 + 11F7 + 11F8 + 11F9

INFORMATION TO BE REPORTED

11F1

Mobile air conditioning equipment for passenger cars

11F2

Mobile air conditioning equipment for buses

11F3

Mobile air conditioning equipment for vans (light duty vehicles)

11F4

Mobile air conditioning equipment for trucks and trailers (heavy duty vehicles)

11F5

Mobile air conditioning equipment for agricultural, forestry and construction vehicles and machinery

11F6

Mobile air conditioning equipment for rail vehicles

11F7

Mobile air conditioning equipment for ships

11F8

Mobile air conditioning equipment for aircrafts and helicopters

11F9

Any other mobile air conditioning equipment

The equipment type/s shall be specified.

AUTOMATICALLY CALCULATED VALUE

11G

Total refrigeration, air conditioning or heat pump equipment

11G = 11A + 11B + 11C + 11D + 11E + 11F

11H

Foam products

11H = 11H1 + 11H2 + 11H3 + 11H4

INFORMATION TO BE REPORTED

11H1

Extruded polystyrene (XPS) insulation boards

Quantities of XPS boards shall be reported in units of cubic metres (next to quantities of contained fluorinated gases in units of metric tonnes)

11H2

Polyurethane (PU) insulation boards

Quantities of PU boards shall be reported in units of cubic metres (next to quantities of contained fluorinated gases in units of metric tonnes)

11H3

One component foam (OCF)

The measurement unit can be pieces of OCF cans (next to quantities of contained fluorinated gases in units of metric tonnes)

11H4

Other foam products

The product category/ies shall be specified.

Imports of pre-blended polyols (e.g. in foam systems/containers) shall not be reported here but rather in section 2.

Quantities of foam products shall be reported in units of either cubic metres, metric tonnes, or pieces of product/equipment (next to quantities of contained fluorinated gases in units of metric tonnes)

11I

Fire protection equipment (including systems incorporated in vehicles)

11J

Medical or pharmaceutical aerosols

11K

Non-medical aerosols

11L

Medical equipment (without aerosols)

11M

Switch gear for transmission and distribution of electricity

11N

Other electrical transmission and distribution equipment

11O

Particle accelerators

11P

Other products and equipment containing gases listed in Annex I or Annex II of Regulation (EU) No 517/2014

The product or equipment category/ies shall be specified.

The measurement unit can be either volume, weight or pieces of product/equipment.

(next to quantities of contained fluorinated gases in units of metric tonnes)

AUTOMATICALLY CALCULATED QUANTITIES

11Q

Total of products and equipment containing fluorinates gases listed in Annex I or Annex II of Regulation (EU) No 517/2014

11Q = 11G + 11H + 11I + 11J + 11K + 11L + 11M + 11N + 11O + 11P

Section 12:To be filled in by importers of refrigeration, air conditioning or heat pump equipment charged with hydrofluorocarbons, where the hydrofluorocarbons contained in the imported equipment had previously been exported from the Union and acquired by manufacturers of equipment directly from the exporting undertaking, and had been subject to the hydrofluorocarbon quota limitation for placing on the Union market — Article 19(5) of Regulation (EU) No 517/2014 and point 6 of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2017 (by 31 March 2018 at the latest).

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each hydrofluorocarbon (gases listed in Section 1 of Annex I to Regulation (EU) No 517/2014 or mixture containing at least one of those gases).

F1INFORMATION TO BE REPORTED

COMMENTS

12A

Amount of hydrofluorocarbons charged into the imported equipment, released by customs for free circulation in the Union, for which the hydrofluorocarbons had previously been exported from the Union and which had been subject to the hydrofluorocarbon quota limitation for placing on the Union market

The hydrofluorocarbon exporting undertaking/s and the year/s of export shall be specified.

The undertaking/s having placed the hydrofluorocarbons on the Union market for the first time and the year/s of that placing on the market shall be specified.

F5Section 13:To be filled in by importers of refrigeration, air conditioning or heat pump equipment charged with hydrofluorocarbons, where the hydrofluorocarbons contained in the equipment are accounted for in the quota system through the use of authorisations — Article 19(5) of Regulation (EU) No 517/2014 and point 6 of Annex VII to Regulation (EU) No 517/2014

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

F6Section 13a:To be filled in by producers and importers of gases – Article 19(1) of Regulation (EU) No 517/2014 and points 1(a) to 1(d); points 2(a), 2(b) and 2(d) and points 3(a) and 3(b) of Annex VII to Regulation (EU) No 517/2014

Applicable for the first time to reporting on activities carried out in 2018 (by 31 March 2019 at the latest) and until and including the year in which Union law ceases to apply to and in the United Kingdom.

Quantities shall be reported in metric tonnes with accuracy to the third decimal place, separately for each gas listed in Section 1 of Annex I to Regulation (EU) No 517/2014 or mixtures containing at least one of those gases or for each gas or mixture contained in pre-blended polyols.

AUTOMATICALLY CALCULATED QUANTITIES

COMMENTS

13aA

Amount of hydrofluorocarbons physically placed on the market, excluding exempted uses

13aA = 4M – Sum of exempted uses in Section 5 (5A – 5F)

INFORMATION TO BE REPORTED

13aB

Thereof: amount placed on the United Kingdom market for the first time

Amounts placed on the United Kingdom market, but subsequently supplied to the Union (without United Kingdom) in bulk are not to be included

Amounts supplied to the United Kingdom market in bulk that were previously placed on the Union (without United Kingdom) market are to be included

AUTOMATICALLY CALCULATED QUANTITIES

13aC

Thereof: amount placed on the Union market, excluding the United Kingdom

13aC = 13aA – 13aB