Commission Delegated Regulation (EU) No 1254/2014Show full title

Commission Delegated Regulation (EU) No 1254/2014 of 11 July 2014 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of residential ventilation units (Text with EEA relevance)

ANNEX IIIU.K.The label

1.Label for UVUs marketed after 1 January 2016:U.K.

F1

The label shall provide the following information:

I.

supplier's name or trade mark;

II.

supplier's model identifier;

III.

energy efficiency; the head of the arrow containing the energy efficiency class of the appliance shall be placed at the same height as the head of the arrow of the relevant energy efficiency class. Energy efficiency is indicated for an ‘average’ climate;

IV.

sound power level (LWA) in dB rounded to the nearest integer;

V.

maximum flow rate in m3/h rounded to the nearest integer, accompanied by one arrow representing UVUs.

2.Label for BVUs marketed after 1 January 2016:U.K.

F2

The label shall provide the following information:

I.

supplier's name or trade mark;

II.

supplier's model identifier;

III.

energy efficiency; the head of the arrow containing the energy efficiency class of the appliance shall be placed at the same height as the head of the arrow of the relevant energy efficiency class. Energy efficiency is indicated for an ‘average’ climate;

IV.

sound power level (LWA) in dB rounded to the nearest integer;

V.

maximum flow rate in m3/h rounded to the nearest integer, accompanied by two arrows in opposite directions representing BVUs.

3.The design of the labels for residential ventilation units set out in points 1 to 2 shall be the following:U.K.

F3

Whereby:

  • The label shall be at least 75 mm wide and 150 mm high. Where the label is printed in a larger format, its content shall nevertheless remain proportionate to the specifications above.

  • The background shall be white.

  • Colours are coded as CMYK — cyan, magenta, yellow and black, following this example: 00-70-X-00: 0 % cyan, 70 % magenta, 100 % yellow, 0 % black.

  • The label shall fulfil all of the following requirements (numbers refer to the figure above):

    EU label border stroke: 3,5 pt — colour: Cyan 100 % — round corners: 2,5 mm.

    [F4UK flag: colours—

    • the blue background: 100,72,00,18.5;

    • the red crosses: 00,100,81,4

    • the remaining part: 100% white;]

    Energy logo: Colour: X-00-00-00.

    Pictogram as depicted: [F5“UK flag] + energy logo: width: 62 mm, height: 12 mm.

    Sub-logos border: 1 pt — colour: cyan 100 % — length: 62 mm.

    A+–G scales:

    • Arrow: height: 6 mm, gap: 1 mm — colours:

      • Highest class: X-00-X-00,

      • Second class: 70-00-X-00,

      • Third class: 30-00-X-00,

      • Fourth class: 00-00-X-00,

      • Fifth class: 00-30-X-00,

      • Sixth class: 00-70-X-00,

      • Seventh class 00-X-X-00,

      • Last class: 00-X-X-00,

    • Text: Calibri bold 13 pt, capitals, white.

    Specific energy consumption class

    • Arrow: width: 17 mm, height: 9 mm, 100 % black;

    • Text: Calibri bold 18,5 pt, capitals, white; ‘+’ symbols: Calibri bold 11 pt, white aligned on a single row.

    Sound power level in dB:

    • Border: 1,5 pt — colour: cyan 100 % — round corners: 2,5 mm;

    • Value: Calibri bold 16 pt, 100 % black;

    • ‘dB’: Calibri regular 10 pt, 100 % black.

    Maximum flow rate in m3/h:

    • Border: 1,5 pt — colour: cyan 100 % — round corners: 2,5 mm;

    • Value: Calibri bold 16 pt, 100 % black;

    • ‘m3/h’: Calibri bold 16 pt, 100 % black;

    • One or two arrows

      • each width: 10 mm, each height: 10 mm.

      • Colour: cyan 100 %.

    Energy:

    • Text: Calibri regular 6 pt, capitals, black.

    Reference period:

    • Text: Calibri bold 8 pt.

    Supplier's name or trademark

    Supplier's model identifier

    The suppliers' name or trade mark and model identifier shall fit in a space of 62 × 10 mm.