2.PRODUCT INFORMATION REQUIREMENTS
From 1 year after entry into force, the following product information shall be provided in the technical documentation of the product, the booklet of instructions and on the free access websites of manufacturers of domestic ovens, hobs and range hoods, their authorised representatives, or importers:
short title or reference to the measurement and calculation methods used to establish compliance with the above requirements;
information relevant to users in order to reduce total environmental impact (e.g. energy use) of the cooking process.
From 1 year after entry into force, the technical documentation and a part for professionals of the free access websites of manufacturers, their authorised representatives, or importers shall contain information relevant for non-destructive disassembly for maintenance purposes and information relevant for dismantling, in particular in relation to the motor, if applicable, and any batteries, recycling, recovery and disposal at end-of-life.
2.1. For domestic ovens
Table 4
Information for domestic ovens
a 1 kWh/cycle = 3,6 MJ/cycle. | |||
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of oven | |||
Mass of the appliance | M | X,X | kg |
Number of cavities | X | ||
Heat source per cavity (electricity or gas) | |||
Volume per cavity | V | X | l |
Energy consumption (electricity) required to heat a standardised load in a cavity of an electric heated oven during a cycle in conventional mode per cavity (electric final energy) | ECelectric cavity | X,XX | kWh/cycle |
Energy consumption required to heat a standardised load in a cavity of an electric heated oven during a cycle in fan-forced mode per cavity (electric final energy) | ECelectric cavity | X,XX | kWh/cycle |
Energy consumption required to heat a standardised load in a gas-fired cavity of an oven during a cycle in conventional mode per cavity (gas final energy) | ECgas cavity | X,XX X,XX | MJ/cycle kWh/cyclea |
Energy consumption required to heat a standardised load in a gas-fired cavity of an oven during a cycle in fan-forced mode per cavity (gas final energy) | ECgas cavity | X,XX X,XX | MJ/cycle kWh/cycle |
Energy Efficiency Index per cavity | EEIcavity | X,X |
2.2. For domestic hobs
2.2.1. Domestic electric hobs
Table 5a
Information for domestic electric hobs
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of hob | |||
Number of cooking zones and/or areas | X | ||
Heating technology (induction cooking zones and cooking areas, radiant cooking zones, solid plates) | |||
For circular cooking zones or area: diameter of useful surface area per electric heated cooking zone, rounded to the nearest 5 mm | Ø | X,X | cm |
For non-circular cooking zones or areas: length and width of useful surface area per electric heated cooking zone or area, rounded to the nearest 5 mm | L W | X,X X,X | cm |
Energy consumption per cooking zone or area calculated per kg | ECelectric cooking | X,X | Wh/kg |
Energy consumption for the hob calculated per kg | ECelectric hob | X,X | Wh/kg |
2.2.2. Domestic gas-fired hobs
Table 5b
Information for domestic gas-fired hobs
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of hob | |||
Number of gas burners | X | ||
Energy efficiency per gas burner | EEgas burner | X,X | |
Energy efficiency for the gas hob | EEgas hob | X,X |
2.2.3. Domestic mixed gas and electric hobs
Table 5c
Information for domestic mixed hobs
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of hob | |||
Number of electric cooking zones and/or areas | X | ||
Heating technology (induction cooking zones and cooking areas, radiant cooking zones, solid plates) per electric cooking zone and/or area | |||
For circular electric cooking zones: diameter of useful surface area per electric heated cooking zone, rounded to the nearest 5 mm | Ø | X,X | cm |
For non-circular electric cooking zones or areas: length and width of useful surface area per electric heated cooking zone or area, rounded to the nearest 5 mm | L W | X,X X,X | cm |
Energy consumption per electric cooking zone or area calculated per kg | ECelectric cooking | X | Wh/kg |
Number of gas fired burners | X | ||
Energy efficiency per gas burner | EEgas burner | X,X |
2.3. For domestic range hoods
Table 6
Information for domestic range hoods
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Annual Energy Consumption | AEChood | X,X | kWh/a |
Time increase factor | f | X,X | |
Fluid Dynamic Efficiency | FDEhood | X,X | |
Energy Efficiency Index | EEIhood | X,X | |
Measured air flow rate at best efficiency point | QBEP | X,X | m3/h |
Measured air pressure at best efficiency point | PBEP | X | Pa |
Maximum air flow | Qmax | X,X | m3/h |
Measured electric power input at best efficiency point | WBEP | X,X | W |
Nominal power of the lighting system | WL | X,X | W |
Average illumination of the lighting system on the cooking surface | Emiddle | X | lux |
Measured power consumption in standby mode | Ps | X,XX | W |
Measured power consumption off mode | Po | X,XX | W |
Sound power level | LWA | X | dB |