xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"

ANNEX IIU.K.

Exhaust emission limits referred to in Article 18(2) U.K.

Table II-1: Stage V emission limits for engine category NRE defined in point (1) of Article 4(1)

a

0,60 for hand-startable, air-cooled direct injection engines.

Emission stageEngine sub-categoryPower rangeIgnition typeCOHCNOxPM massPNA
kWg/kWhg/kWhg/kWhg/kWh#/kWh
Stage V

NRE-v-1

NRE-c-1

0 < P < 8CI8,00(HC + NOx ≤ 7,50)0,40a1,10
Stage V

NRE-v-2

NRE-c-2

8 ≤ P < 19CI6,60(HC + NOx ≤ 7,50)0,401,10
Stage V

NRE-v-3

NRE-c-3

19 ≤ P < 37CI5,00(HC + NOx ≤ 4,70)0,0151 × 10121,10
Stage V

NRE-v-4

NRE-c-4

37 ≤ P < 56CI5,00(HC + NOx ≤ 4,70)0,0151 × 10121,10
Stage V

NRE-v-5

NRE-c-5

56 ≤ P < 130all5,000,190,400,0151 × 10121,10
Stage V

NRE-v-6

NRE-c-6

130 ≤ P ≤ 560all3,500,190,400,0151 × 10121,10
Stage V

NRE-v-7

NRE-c-7

P > 560all3,500,193,500,0456,00

Table II-2: Stage V emission limits for engine category NRG defined in point (2) of Article 4(1)

Emission stageEngine sub-categoryPower rangeIgnition typeCOHCNOxPM massPNA
kWg/kWhg/kWhg/kWhg/kWh#/kWh
Stage V

NRG-v-1

NRG-c-1

P > 560all3,500,190,670,0356,00

Table II-3: Stage V emission limits for engine category NRSh defined in point (3) of Article 4(1)

Emission stageEngine sub-categoryPower rangeIgnition typeCOHC + NOx
kWg/kWhg/kWh
Stage VNRSh-v-1a0 < P < 19SI80550
Stage VNRSh-v-1b60372

Table II-4: Stage V emission limits for engine category NRS defined in point (4) of Article 4(1)

a

Optionally, as an alternative, any combination of values satisfying the equation (HC + NOX) × CO0,784 ≤ 8,57 as well as the following conditions: CO ≤ 20,6 g/kWh and (HC + NOX) ≤ 2,7 g/kWh

Emission stageEngine sub-categoryPower rangeIgnition typeCOHC + NOx
kWg/kWhg/kWh
Stage V

NRS-vr-1a

NRS-vi-1a

0 < P < 19SI61010
Stage V

NRS-vr-1b

NRS-vi-1b

6108
Stage VNRS-v-2a19 ≤ P ≤ 306108
Stage V

NRS-v-2b

NRS-v-3

19 ≤ P < 564,40a2,70a

Table II-5: Stage V emission limits for engine category IWP defined in point (5) of Article 4(1)

Emission stageEngine sub-categoryPower rangeIgnition typeCOHCNOxPM massPNA
kWg/kWhg/kWhg/kWhg/kWh#/kWh
Stage V

IWP-v-1

IWP-c-1

19 ≤ P < 75all5,00(HC + NOx ≤ 4,70)0,306,00
Stage V

IWP-v-2

IWP-c-2

75 ≤ P < 130all5,00(HC + NOx ≤ 5,40)0,146,00
Stage V

IWP-v-3

IWP-c-3

130 ≤ P < 300all3,501,002,100,106,00
Stage V

IWP-v-4

IWP-c-4

P ≥ 300all3,500,191,800,0151 × 10126,00

Table II-6: Stage V emission limits for engine category IWA defined in point (6) of Article 4(1)

Emission stageEngine sub-categoryPower rangeIgnition typeCOHCNOxPM massPNA
kWg/kWhg/kWhg/kWhg/kWh#/kWh
Stage V

IWA-v-1

IWA-c-1

19 ≤ P < 75all5,00(HC + NOx ≤ 4,70)0,306,00
Stage V

IWA-v-2

IWA-c-2

75 ≤ P < 130all5,00(HC + NOx ≤ 5,40)0,146,00
Stage V

IWA-v-3

IWA-c-3

130 ≤ P < 300all3,501,002,100,106,00
Stage V

IWA-v-4

IWA-c-4

P ≥ 300all3,500,191,800,0151 × 10126,00

Table II-7: Stage V emission limits for engine category RLL defined in point (7) of Article 4(1)

Emission stageEngine sub-categoryPower rangeIgnition typeCOHCNOxPM massPNA
kWg/kWhg/kWhg/kWhg/kWh#/kWh
Stage V

RLL-c-1

RLL-v-1

P > 0all3,50(HC + NOx ≤ 4,00)0,0256,00

Table II-8: Stage V emission limits for engine category RLR defined in point (8) of Article 4(1)

Emission stageEngine sub-categoryPower rangeIgnition typeCOHCNOxPM massPNA
kWg/kWhg/kWhg/kWhg/kWh#/kWh
Stage V

RLR-c-1

RLR-v-1

P > 0all3,500,192,000,0151 × 10126,00

Table II-9: Stage V emission limits for engine category SMB defined in point (9) of Article 4(1)

Emission stageEngine sub-categoryPower rangeIgnition typeCONOxHC
kWg/kWhg/kWhg/kWh
Stage VSMB-v-1P > 0SI27575

Table II-10: Stage V emission limits for engine category ATS defined in point (10) of Article 4(1)

Emission stageEngine sub-categoryPower rangeIgnition typeCOHC + NOx
kWg/kWhg/kWh
Stage VATS-v-1P > 0SI4008

Specific provisions on total hydrocarbon (HC) limits for fully and partially gaseous-fuelled engines U.K.

1.For the sub-categories where an A-factor is defined, the HC limit for fully and partially gaseous-fuelled engines indicated in Tables II-1 to II-10 is replaced by a limit calculated using the following formula:U.K.

HC = 0,19 + (1,5 × A × GER)

where GER is the average gas energy ratio over the appropriate test cycle. Where both a steady-state and transient test cycle apply, the GER shall be determined from the hot-start transient test cycle. Where more than one steady-state test cycle applies, the average GER shall be determined for each cycle individually.

If the calculated limit for HC exceeds the value of 0,19 + A, the limit for HC shall be set to 0,19 + A.

2.For sub-categories with a combined HC and NOx limit, the combined limit value for HC and NOx shall be reduced by 0,19 g/kWh and apply for NOx only.U.K.

3.For non-gaseous-fuelled engines, the formula does not apply.U.K.