ANNEX IXU.K. VERIFYING TRUCK AUXILIARY DATA
1.IntroductionU.K.
This Annex describes the provisions regarding the power consumption of auxiliaries for heavy duty vehicles for the purpose of the determination of vehicle specific CO2 emissions.
[F1The power consumption of the following auxiliaries shall be considered within the simulation tool by using technology specific average standard power values:]
Textual Amendments
F1 Substituted by Commission Regulation (EU) 2019/318 of 19 February 2019 amending Regulation (EU) 2017/2400 and Directive 2007/46/EC of the European Parliament and of the Council as regards the determination of the CO2 emissions and fuel consumption of heavy-duty vehicles (Text with EEA relevance).
Fan
Steering system
Electric system
Pneumatic system
Air Conditioning (AC) system
Transmission Power Take Off (PTO)
[F1The standard values are integrated in the simulation tool and automatically used by choosing the corresponding technology.]
2.DefinitionsU.K.
For the purposes of this Annex the following definitions shall apply:
‘Crankshaft mounted fan’ means a fan installation where the fan is driven in the prolongation of the crankshaft, often by a flange;
‘Belt or transmission driven fan’ means a fan that is installed in a position where additional belt, tension system or transmission is needed;
‘Hydraulic driven fan’ means a fan propelled by hydraulic oil, often installed away from the engine. A hydraulic system with oil system, pump and valves are influencing losses and efficiencies in the system;
‘Electrically driven fan’ means a fan propelled by an electric motor. The efficiency for complete energy conversion, included in/out from battery, is considered;
‘Electronically controlled visco clutch’ means a clutch in which a number of sensor inputs together with SW logic are used to electronically actuate the fluid flow in the visco clutch;
‘Bimetallic controlled visco clutch’ means a clutch in which a bimetallic connection is used to convert a temperature change into mechanical displacement. The mechanical displacement is then working as an actuator for the visco clutch;
‘Discrete step clutch’ means a mechanical device where the grade of actuation can be made in distinct steps only (not continuous variable).
‘On/off clutch’ means a mechanical clutch which is either fully engaged or fully disengaged;
‘Variable displacement pump’ means a device that converts mechanical energy to hydraulic fluid energy. The amount of fluid pumped per revolution of the pump can be varied while the pump is running;
‘Constant displacement pump’ means a device that converts mechanical energy to hydraulic fluid energy. The amount of fluid pumped per revolution of the pump cannot be varied while the pump is running;
‘Electric motor control’ means the use of an electric motor to propel the fan. The electrical machine converts electrical energy into mechanical energy. Power and speed are controlled by conventional technology for electric motors;
‘Fixed displacement pump (default technology)’ means a pump having an internal limitation of the flow rate;
‘Fixed displacement pump with electronic control’ means a pump using an electronic control of the flow rate;
‘Dual displacement pump’ means a pump with two chambers (with the same or different displacement) which can be combined or only one of these is used. It is characterised by an internal limitation of flow rate;
‘Variable displacement pump mech. controlled’ means a pump where the displacement is mechanically controlled internally (internal pressure scales);
‘Variable displacement pump elec. controlled’ means a pump where the displacement is mechanically controlled internally (internal pressure scales). Additionally, the flow rate is elec. controlled by a valve;
[F1‘ Electric steering pump ’ means a hydraulic pump driven by an electric motor;]
‘Baseline air compressor’ means a conventional air compressor without any fuel saving technology;
‘Air compressor with Energy Saving System (ESS)’ means a compressor reducing the power consumption during blow off, e.g. by closing intake side, ESS is controlled by system air pressure;
‘Compressor clutch (visco)’ means a disengageable compressor where the clutch is controlled by the system air pressure (no smart strategy), minor losses during disengaged state caused by visco clutch;
‘Compressor clutch (mechanically)’ means a disengageable compressor where the clutch is controlled by the system air pressure (no smart strategy);
‘Air Management System with optimal regeneration (AMS)’ means an electronic air processing unit that combines an electronically controlled air dryer for optimized air regeneration and an air delivery preferred during overrun conditions (requires a clutch or ESS).
‘Light Emitting Diodes (LED)’ mean semiconductor devices that emit visible light when an electrical current passes through them.
‘Air conditioning system’ means a system consisting of a refrigerant circuit with compressor and heat exchangers to cool down the interior of a truck cab or bus body.
‘Power take-off (PTO)’ means a device on a transmission or an engine to which an auxiliary driven device, e.g., a hydraulic pump, can be connected; a power take-off is usually optional;
‘Power take-off drive mechanism’ means a device in a transmission that allows the installation of a power take-off (PTO);
‘Tooth clutch’ means a (manoeuvrable) clutch where torque is transferred mainly by normal forces between mating teeth. A tooth clutch can either be engaged or disengaged. It is operated in load-free conditions only (e.g. at gear shifts in a manual transmission);
‘Synchroniser’ means a type of tooth clutch where a friction device is used to equalise the speeds of the rotating parts to be engaged;
‘Multi-disc clutch’ means a clutch where several friction linings are arranged in parallel whereby all friction pairs get the same pressing force. Multi-disc clutches are compact and can be engaged and disengaged under load. They may be designed as dry or wet clutches;
‘Sliding wheel’ means a gearwheel used as shift element where the shifting is realized by moving the gearwheel on its shaft into or out of the gear mesh of the mating gear.
3.Determination of technology specific average standard power valuesU.K.
3.1FanU.K.
For the fan power the standard values shown in Table 1 shall be used depending on mission profile and technology:
Table 1
Mechanical power demand of the fan
Fan drive cluster | Fan control | Fan power consumption [W] | ||||
---|---|---|---|---|---|---|
Long haul | Regional delivery | Urban delivery | Municipal utility | Construction | ||
Crankshaft mounted | Electronically controlled visco clutch | 618 | 671 | 516 | 566 | 1 037 |
Bimetallic controlled visco clutch | 818 | 871 | 676 | 766 | 1 277 | |
Discrete step clutch | 668 | 721 | 616 | 616 | 1 157 | |
On/off cluch | 718 | 771 | 666 | 666 | 1 237 | |
Belt driven or driven via transmission | Electronic controlled visco clutch | 989 | 1 044 | 833 | 933 | 1 478 |
Bimetallic controlled visco clutch | 1 189 | 1 244 | 993 | 1 133 | 1 718 | |
Discrete step clutch | 1 039 | 1 094 | 983 | 983 | 1 598 | |
On/off cluch | 1 089 | 1 144 | 1 033 | 1 033 | 1 678 | |
Hydraulically driven | Variable displacement pump | 938 | 1 155 | 832 | 917 | 1 872 |
Constant displacement pump | 1 200 | 1 400 | 1 000 | 1 100 | 2 300 | |
Electrically driven | Electronically | 700 | 800 | 600 | 600 | 1 400 |
If a new technology within a fan drive cluster (e.g. crankshaft mounted) cannot be found in the list the highest power values within that cluster shall be taken. If a new technology cannot be found in any cluster the values of the worst technology at all shall be taken (hydraulic driven constant displacement pump)
3.2Steering SystemU.K.
For the steering pump power the standard values [W] shown in Table 2 shall be used depending on the application in combination with correction factors:
[F1Table 2
Mechanical power demand of steering pump
Identification of vehicle configuration | Steering power consumption P [W] | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of axles | Axle configuration | Chassis configuration | Technically permissible maximum laden mass (tons) | Vehicle group | Long haul | Regional delivery | Urban delivery | Municipal utility | Construction | ||||||||||
U+F | B | S | U + F | B | S | U + F | B | S | U + F | B | S | U + F | B | S | |||||
2 | 4 × 2 | Rigid lorry + (Tractor) | > 7,5 - 10 | 1 | 240 | 20 | 20 | 220 | 20 | 30 | |||||||||
Rigid lorry + (Tractor) | > 10 - 12 | 2 | 340 | 30 | 0 | 290 | 30 | 20 | 260 | 20 | 30 | ||||||||
Rigid lorry + (Tractor) | > 12 - 16 | 3 | 310 | 30 | 30 | 280 | 30 | 40 | |||||||||||
Rigid lorry | > 16 | 4 | 510 | 100 | 0 | 490 | 40 | 40 | 430 | 40 | 50 | 430 | 30 | 50 | 580 | 30 | 70 | ||
Tractor | > 16 | 5 | 600 | 120 | 0 | 540 | 90 | 40 | 640 | 50 | 80 | ||||||||
4 × 4 | Rigid lorry | > 7,5 - 16 | 6 | — | |||||||||||||||
Rigid lorry | > 16 | 7 | — | ||||||||||||||||
Tractor | > 16 | 8 | — | ||||||||||||||||
3 | 6 × 2/2 – 4 | Rigid lorry | all | 9 | 600 | 120 | 0 | 490 | 60 | 40 | 440 | 50 | 50 | 430 | 30 | 50 | 640 | 50 | 80 |
Tractor | all | 10 | 450 | 120 | 0 | 440 | 90 | 40 | 640 | 50 | 80 | ||||||||
6 × 4 | Rigid lorry | all | 11 | 600 | 120 | 0 | 490 | 60 | 40 | 430 | 30 | 50 | 640 | 50 | 80 | ||||
Tractor | all | 12 | 450 | 120 | 0 | 440 | 90 | 40 | 640 | 50 | 80 | ||||||||
6 × 6 | Rigid lorry | all | 13 | — | |||||||||||||||
Tractor | all | 14 | |||||||||||||||||
4 | 8 × 2 | Rigid lorry | all | 15 | — | ||||||||||||||
8 × 4 | Rigid lorry | all | 16 | 640 | 50 | 80 | |||||||||||||
8 × 6/8 × 8 | Rigid lorry | all | 17 | — |
where:
=
Unloaded – pumping oil without steering pressure demand
=
Friction – friction in the pump
=
Banking – steer correction due to banking of the road or side wind
=
Steering – steer pump power demand due to cornering and manoeuvring.]
To consider the effect of different technologies, technology depending scaling factors as shown in Table 3 and Table 4 shall be applied.
Table 3
Scaling factors depending on technology
Factor c1 depending on technology | |||
---|---|---|---|
Technology | c1,U + F | c1,B | c1,S |
Fixed displacement | 1 | 1 | 1 |
Fixed displacement with electronical control | 0,95 | 1 | 1 |
Dual displacement | 0,85 | 0,85 | 0,85 |
Variable displacement, mech. controlled | 0,75 | 0,75 | 0,75 |
Variable displacement, elec. controlled | 0,6 | 0,6 | 0,6 |
Electric | 0 | 1,5/ηalt | 1/ηalt |
with ηalt = alternator efficiency = const. = 0,7
[F1If a new technology is not listed, the technology ‘ fixed displacement ’ shall be considered in the simulation tool.]
Table 4
Scaling factor depending on number of steered axles
Factor c2 depending on number of steered axles | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of steered axles | Long haul | Regional delivery | Urban delivery | Municipal utility | Construction | ||||||||||
c2,U+F | c2,B | c2,S | c2,U+F | c2,B | c2,S | c2,U+F | c2,B | c2,S | c2,U+F | c2,B | c2,S | c2,U+F | c2,B | c2,S | |
1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
2 | 1 | 0,7 | 0,7 | 1,0 | 0,7 | 0,7 | 1,0 | 0,7 | 0,7 | 1,0 | 0,7 | 0,7 | 1,0 | 0,7 | 0,7 |
3 | 1 | 0,5 | 0,5 | 1,0 | 0,5 | 0,5 | 1,0 | 0,5 | 0,5 | 1,0 | 0,5 | 0,5 | 1,0 | 0,5 | 0,5 |
4 | 1,0 | 0,5 | 0,5 | 1,0 | 0,5 | 0,5 | 1,0 | 0,5 | 0,5 | 1,0 | 0,5 | 0,5 | 1,0 | 0,5 | 0,5 |
The final power demand is calculated by:
If different technologies are used for multi-steered axles, the mean values of the corresponding factors c1 shall be used.
The final power demand is calculated by:
Ptot = Σi(PU + F * mean(c1,U +F ) * (c2i,U + F)) + Σi(PB * mean(c1,B) * (c2i,B)) + Σi(PS * mean(c1,S) * (c2i,S))
where:
=
Total power demand [W]
=
Power demand [W]
=
Correction factor depending on technology
=
Correction factor depending on number of steered axles
=
Unloaded + friction [-]
=
Banking [-]
=
Steering [-]
=
Number of steered axles [-]
3.3Electric systemU.K.
For the electric system power the standard values [W] as shown in Table 5 shall be used depending on the application and technology in combination with the alternator efficiencies:
Table 5
Electrical power demand of electric system
Technologies influencing electric power consumption | Electric power consumption [W] | ||||
---|---|---|---|---|---|
Long haul | Regional delivery | Urban delivery | Municipal utility | Construction | |
Standard technology electric power [W] | 1 200 | 1 000 | 1 000 | 1 000 | 1 000 |
LED main front headlights | – 50 | – 50 | – 50 | – 50 | – 50 |
To derive the mechanical power, an alternator technology dependent efficiency factor as shown in Table 6 shall be applied.
Table 6
Alternator efficiency factor
Alternator (power conversion) technologiesGeneric efficiency values for specific technologies | Efficiency ηalt | ||||
---|---|---|---|---|---|
Long haul | Regional delivery | Urban delivery | Municipal utility | Construction | |
Standard alternator | 0,7 | 0,7 | 0,7 | 0,7 | 0,7 |
[F1If the technology used in the vehicle is not listed, the technology ‘ standard alternator ’ shall be considered in the simulation tool.]
The final power demand is calculated by:
where:
=
Total power demand [W]
=
Electrical power demand [W]
=
Alternator efficiency [-]
3.4Pneumatic systemU.K.
For pneumatic systems working with over pressure the standard power values [W] as shown in Table 7 shall be used depending on application and technology.
Table 7
Mechanical power demand of pneumatic systems (over pressure)
Size of air supply | Technology | Long Haul | Regional Delivery | Urban Delivery | Municipal Utility | Construction |
---|---|---|---|---|---|---|
Pmean | Pmean | Pmean | Pmean | Pmean | ||
[W] | [W] | [W] | [W] | [W] | ||
small displ. ≤ 250 cm3 1 cyl./2 cyl. | Baseline | 1 400 | 1 300 | 1 200 | 1 200 | 1 300 |
+ ESS | – 500 | – 500 | – 400 | – 400 | – 500 | |
+ visco clutch | – 600 | – 600 | – 500 | – 500 | – 600 | |
+ mech. clutch | – 800 | – 700 | – 550 | – 550 | – 700 | |
+ AMS | – 400 | – 400 | – 300 | – 300 | – 400 | |
medium 250 cm3 < displ. ≤ 500 cm3 1 cyl./2 cyl. 1-stage | Baseline | 1 600 | 1 400 | 1 350 | 1 350 | 1 500 |
+ ESS | – 600 | – 500 | – 450 | – 450 | – 600 | |
+ visco clutch | – 750 | – 600 | – 550 | – 550 | – 750 | |
+ mech. clutch | – 1 000 | – 850 | – 800 | – 800 | – 900 | |
+ AMS | – 400 | – 200 | – 200 | – 200 | – 400 | |
medium 250 cm3 < displ. ≤ 500 cm3 1 cyl./2 cyl. 2-stage | Baseline | 2 100 | 1 750 | 1 700 | 1 700 | 2 100 |
+ ESS | – 1 000 | – 700 | – 700 | – 700 | – 1 100 | |
+ visco clutch | – 1 100 | – 900 | – 900 | – 900 | – 1 200 | |
+ mech. clutch | – 1 400 | – 1 100 | – 1 100 | – 1 100 | – 1 300 | |
+ AMS | – 400 | – 200 | – 200 | – 200 | – 500 | |
large displ. > 500 cm3 1 cyl./2 cyl. 1-stage/2-stage | Baseline | 4 300 | 3 600 | 3 500 | 3 500 | 4 100 |
+ ESS | – 2 700 | – 2 300 | – 2 300 | – 2 300 | – 2 600 | |
+ visco clutch | – 3 000 | – 2 500 | – 2 500 | – 2 500 | – 2 900 | |
+ mech. clutch | – 3 500 | – 2 800 | – 2 800 | – 2 800 | – 3 200 | |
+ AMS | – 500 | – 300 | – 200 | – 200 | – 500 |
For pneumatic systems working with vacuum (negative pressure) the standard power values [W] as shown in Table 8 shall be used.
Table 8
Mechanical power demand of pneumatic systems (vacuum pressure)
Long Haul | Regional Delivery | Urban Delivery | Municipal Utility | Construction | |
---|---|---|---|---|---|
Pmean | Pmean | Pmean | Pmean | Pmean | |
[W] | [W] | [W] | [W] | [W] | |
Vacuum pump | 190 | 160 | 130 | 130 | 130 |
Fuel saving technologies can be considered by subtracting the corresponding power demand from the power demand of the baseline compressor.
The following combinations of technologies are not considered:
ESS and clutches
Visco clutch and mechanical clutch
In case of a two-stage compressor, the displacement of the first stage shall be used to describe the size of the air compressor system
3.5Air Conditioning systemU.K.
For vehicles having an air conditioning system, the standard values [W] as shown in Table 9 shall be used depending on the application.
[F1Table 9
Mechanical power demand of AC system
Identification of vehicle configuration | AC power consumption [W] | ||||||||
---|---|---|---|---|---|---|---|---|---|
Number of axles | Axle configuration | Chassis configuration | Technically permissible maximum laden mass (tons) | Vehicle group | Long haul | Regional delivery | Urban delivery | Municipal utility | Construction |
2 | 4 × 2 | Rigid lorry + (Tractor) | > 7,5 - 10 | 1 | 150 | 150 | |||
Rigid lorry + (Tractor) | > 10 - 12 | 2 | 200 | 200 | 150 | ||||
Rigid lorry + (Tractor) | > 12 - 16 | 3 | 200 | 150 | |||||
Rigid lorry | > 16 | 4 | 350 | 200 | 150 | 300 | 200 | ||
Tractor | > 16 | 5 | 350 | 200 | 200 | ||||
4 × 4 | Rigid lorry | > 7,5 - 16 | 6 | — | |||||
Rigid lorry | > 16 | 7 | — | ||||||
Tractor | > 16 | 8 | — | ||||||
3 | 6 × 2/2 – 4 | Rigid lorry | all | 9 | 350 | 200 | 150 | 300 | 200 |
Tractor | all | 10 | 350 | 200 | 200 | ||||
6 × 4 | Rigid lorry | all | 11 | 350 | 200 | 300 | 200 | ||
Tractor | all | 12 | 350 | 200 | 200 | ||||
6 × 6 | Rigid lorry | all | 13 | — | |||||
Tractor | all | 14 | |||||||
4 | 8 × 2 | Rigid lorry | all | 15 | — | ||||
8 × 4 | Rigid lorry | all | 16 | 200 | |||||
8 × 6/8 × 8 | Rigid lorry | all | 17 | —] |
3.6Transmission Power Take-Off (PTO)U.K.
For vehicles with PTO and/or PTO drive mechanism installed on the transmission, the power consumption shall be considered by determined standard values. The corresponding standard values represent these power losses in usual drive mode when the PTO is switched off/disengaged. [F1Application related power consumptions at engaged PTO are added by the simulation tool and are not described in the following.]
Table 10
Mechanical power demand of switched off/disengaged power take-off
Design variants regarding power losses (in comparison to a transmission without PTO and / or PTO drive mechanism) | |||
---|---|---|---|
Additional drag loss relevant parts | PTO incl. drive mechanism | only PTO drive mechanism | |
Shafts / gear wheels | Other elements | Power loss [W] | Power loss [W] |
only one engaged gearwheel positioned above the specified oil level (no additional gearmesh) | — | — | 0 |
only the drive shaft of the PTO | tooth clutch (incl. synchroniser) or sliding gearwheel | 50 | 50 |
only the drive shaft of the PTO | multi-disc clutch | 1 000 | 1 000 |
only the drive shaft of the PTO | multi-disc clutch and oil pump | 2 000 | 2 000 |
drive shaft and/or up to 2 engaged gearwheels | tooth clutch (incl. synchroniser) or sliding gearwheel | 300 | 300 |
drive shaft and/or up to 2 engaged gearwheels | multi-disc clutch | 1 500 | 1 500 |
drive shaft and/or up to 2 engaged gearwheels | multi-disc clutch and oil pump | 3 000 | 3 000 |
drive shaft and/or more than 2 engaged gearwheels | tooth clutch (incl. synchroniser) or sliding gearwheel | 600 | 600 |
drive shaft and/or more than 2 engaged gearwheels | multi-disc clutch | 2 000 | 2 000 |
drive shaft and/or more than 2 engaged gearwheels | multi-disc clutch and oil pump | 4 000 | 4 000 |