Input parameters for the simulation tool U.K.
IntroductionU.K.
This Appendix describes the list of parameters to be provided by the component manufacturer as input to the simulation tool. The applicable XML schema as well as example data are available at the dedicated electronic distribution platform.
The XML is automatically generated by the engine pre-processing tool.
DefinitionsU.K.
Unique identifier as used in the simulation tool for a specific input parameter or set of input data]
Data type of the parameter
sequence of characters in ISO8859-1 encoding
sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace
date and time in UTC time in the format: YYYY-MM-DDTHH:MM:SSZ with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’
value with an integral data type, no leading zeros, e.g. ‘1800’
fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’
physical unit of the parameter
Textual Amendments
F1 Substituted by Commission Regulation (EU) 2019/318 of 19 February 2019 amending Regulation (EU) 2017/2400 and Directive 2007/46/EC of the European Parliament and of the Council as regards the determination of the CO2 emissions and fuel consumption of heavy-duty vehicles (Text with EEA relevance).
Set of input parametersU.K.
Table 1
Input parameters ‘Engine/General’
Parameter name | Parameter ID | Type | Unit | Description/Reference |
---|---|---|---|---|
Manufacturer | P200 | token | [-] | |
Model | P201 | token | [-] | |
[F1CertificationNumber | P202 | token | [-] | ] |
Date | P203 | dateTime | [-] | Date and time when the component-hash is created |
AppVersion | P204 | token | [-] | Version number of engine pre-processing tool |
Displacement | P061 | int | [cm3] | |
IdlingSpeed | P063 | int | [1/min] | |
RatedSpeed | P249 | int | [1/min] | |
RatedPower | P250 | int | [W] | |
MaxEngineTorque | P259 | int | [Nm] | |
WHTCUrban | P109 | double, 4 | [-] | |
WHTCRural | P110 | double, 4 | [-] | |
WHTCMotorway | P111 | double, 4 | [-] | |
BFColdHot | P159 | double, 4 | [-] | |
CFRegPer | P192 | double, 4 | [-] | |
CFNCV | P260 | double, 4 | [-] | |
[F1FuelType | P193 | string | [-] | Allowed values: ‘ Diesel CI ’ , ‘ Ethanol CI ’ , ‘ Petrol PI ’ , ‘ Ethanol PI ’ , ‘ LPG PI ’ , ‘ NG PI ’ , ‘ NG CI ’] |
Table 2
Input parameters ‘Engine/FullloadCurve’ for each grid point in the full load curve
Parameter name | Parameter ID | Type | Unit | Description/Reference |
---|---|---|---|---|
EngineSpeed | P068 | double, 2 | [1/min] | |
MaxTorque | P069 | double, 2 | [Nm] | |
DragTorque | P070 | double, 2 | [Nm] |
Table 3
Input parameters ‘Engine/FuelMap’ for each grid point in the fuel map
Parameter name | Parameter ID | Type | Unit | Description/Reference |
---|---|---|---|---|
EngineSpeed | P072 | double, 2 | [1/min] | |
Torque | P073 | double, 2 | [Nm] | |
FuelConsumption | P074 | double, 2 | [g/h] |