4.2.Option B: Measurement at constant input torque (in accordance with SAE J643)U.K.
4.2.1.General requirementsU.K.
As specified in 4.1.1.
4.2.2.Oil temperatureU.K.
As specified in 4.1.2.
4.2.3.Oil flow rate and pressureU.K.
As specified in 4.1.3.
4.2.4.Oil qualityU.K.
As specified in 4.1.4.
4.2.5.InstallationU.K.
As specified in 4.1.5.
4.2.6.Measurement equipmentU.K.
As specified in 4.1.6.
4.2.7.Test procedureU.K.
4.2.7.1.Zero torque signal compensationU.K.
As specified in 3.1.6.1.
4.1.7.2.Measurement sequenceU.K.
4.2.7.2.1.The input torque Tpum shall be set to a positive level at npum = 1 000 rpm with the output shaft of the TC held non-rotating (output speed ntur = 0 rpm).U.K.
4.2.7.2.2.The speed ratio v shall be adjusted by increasing the output speed ntur from 0 rpm up to a value of ntur covering the usable range of v with at least seven evenly distributed speed points.U.K.
4.2.7.2.3.The step width shall be 0.1 for the speed ratio range of 0 to 0,6 and 0,05 for the range of 0,6 to 0,95.U.K.
4.2.7.2.4.The upper limit of the speed ratio may be limited to a value below 0,95 by the manufacturer.U.K.
4.2.7.2.5.For each step a minimum of 5 seconds stabilization time within the temperature limits defined in 4.2.2. is required. If needed, the stabilization time may be extended by the manufacturer to maximum 60 seconds. The oil temperature shall be recorded during the stabilization.U.K.
4.2.7.2.6.For each step the values specified in 4.2.8. shall be shall be recorded for the test point for 05-15 seconds.U.K.
4.2.7.2.7.The measurement sequence (4.2.7.2.1. to 4.2.7.2.6.) shall be performed two times in total.U.K.
4.2.8.Measurement signals and data recordingU.K.
As specified in 4.1.8.
4.2.9.Measurement validationU.K.
As specified in 4.1.9.
4.2.10.Measurement uncertaintyU.K.
As specified in 4.1.9.
4.2.11.Calculation of TC characteristicsU.K.
As specified in 4.1.11.