1.The operator shall determine the annual emissions from an emission source over the reporting period by summing up over the reporting period all hourly values of the measured greenhouse gas concentration multiplied by the hourly values of the flue gas flow, where the hourly values shall be averages over all individual measurement results of the respective operating hour.
In the case of CO2 emissions, the operator shall determine annual emissions on the basis of equation 1 in Annex VIII. CO emitted to the atmosphere shall be treated as the molar equivalent amount of CO2.
In the case of nitrous oxide (N2O), the operator shall determine annual emissions on the basis of the equation in subsection B.1 of section 16 of Annex IV.
2.Where several emission sources exist in one installation and cannot be measured as one emission source, the operator shall measure emissions from those sources separately and add the results to obtain the total emissions of the gas in question over the reporting period.
3.The operator shall determine the greenhouse gas concentration in the flue gas by continuous measurement at a representative point through one of the following:
(a)direct measurement;
(b)in the case of high concentration in the flue gas, calculation of the concentration using an indirect concentration measurement applying equation 3 in Annex VIII and taking into account the measured concentration values of all other components of the gas stream as laid down in the operator's monitoring plan.
4.Where relevant, the operator shall determine separately any CO2 amount stemming from biomass and subtract it from the total measured CO2 emissions. For this purpose the operator may use:
(a)a calculation based approach, including approaches using analyses and sampling based on EN ISO 13833 (Stationary source emissions — Determination of the ratio of biomass (biogenic) and fossil-derived carbon dioxide — Radiocarbon sampling and determination);
(b)another method based on a relevant standard, including ISO 18466 (Stationary source emissions — Determination of the biogenic fraction in CO2 in stack gas using the balance method);
(c)an estimation method published by the Commission.
Where the method proposed by the operator involves continuous sampling from the flue gas stream, EN 15259 (Air quality — Measurement of stationary source emissions — Requirements for measurement sections and sites and for the measurement objective, plan and report) shall be applied.
5.The operator shall determine the flue gas flow for the calculation in accordance with paragraph 1 by one of the following methods:
(a)calculation by means of a suitable mass balance, taking into account all significant parameters on the input side, including for CO2 emissions at least input material loads, input airflow and process efficiency, and on the output side, including at least the product output and the concentration of oxygen (O2), sulphur dioxide (SO2) and nitrogen oxides (NOx);
(b)determination by continuous flow measurement at a representative point.