Article 44U.K.Data aggregation
1.The operator shall calculate hourly averages for each parameter, including concentrations and flue gas flow, relevant for determining emissions using a measurement-based methodology by using all data points available for that specific hour.
Where an operator can generate data for shorter reference periods without additional cost, the operator shall use those periods for the determination of the annual emissions in accordance with Article 43(1).
2.Where the continuous measurement equipment for a parameter is out of control, out of range or out of operation for part of the hour or reference period referred to in paragraph 1, the operator shall calculate the related hourly average pro rata to the remaining data points for that specific hour or shorter reference period, provided that at least 80 % of the maximum number of data points for a parameter are available.
Article 45(2) to (4) shall apply where fewer than 80 % of the maximum number of data points for a parameter are available.