CHAPTER VU.K. DATA MANAGEMENT AND CONTROL

Article 60U.K.Quality assurance

1.For the purposes of point (a) of Article 59(3), the operator shall ensure that all relevant measuring equipment is calibrated, adjusted and checked at regular intervals, including prior to use, and checked against measurement standards traceable to international measurement standards, where available, in accordance with the requirements of this Regulation and proportionate to the risks identified.

Where components of the measuring systems cannot be calibrated, the operator shall identify those in the monitoring plan and propose alternative control activities.

When the equipment is found not to comply with required performance, the operator shall promptly take necessary corrective action.

2.With regard to continuous emission measurement systems, the operator shall apply quality assurance based on the standard Quality assurance of automated measuring systems (EN 14181), including parallel measurements with standard reference methods at least once per year, performed by competent staff.

Where such quality assurance requires emission limit values (ELVs) as necessary parameters for the basis of calibration and performance checks, the annual average hourly concentration of the greenhouse gas shall be used as a substitute for such ELVs. Where the operator finds a non-compliance with the quality assurance requirements, including that recalibration has to be performed, it shall report that circumstance to the competent authority and take corrective action without undue delay.