Search Legislation

Commission Regulation (EU) 2019/1782Show full title

Commission Regulation (EU) 2019/1782 of 1 October 2019 laying down ecodesign requirements for external power supplies pursuant to Directive 2009/125/EC of the European Parliament and of the Council and repealing Commission Regulation (EC) No 278/2009 (Text with EEA relevance)

 Help about what version

What Version

 Help about advanced features

Advanced Features

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Changes to legislation:

There are currently no known outstanding effects for the Commission Regulation (EU) 2019/1782, Division 2.. Help about Changes to Legislation

Close

Changes to Legislation

Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

2.Information requirements:U.K.

(a)

from 1 April 2020, the nameplate shall include the following information:

Nameplate informationValue and precisionUnitNotes
Output powerX,XWIn cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be given.
Output voltageX,XVIn cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be given.
Output currentX,XAIn cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be given.
(b)

from 1 April 2020, instruction manuals for end-users (where applicable), and free access websites of manufacturers, importers or authorised representatives shall include the following information, in the order as set out below:

Information publishedValue and precisionUnitNotes
Manufacturer’s name or trade mark, commercial registration number and address---
Model identifier---
Input voltageXVSpecified by the manufacturer. Shall be a value or a range.
Input AC frequencyXHzSpecified by the manufacturer. Shall be a value or a range.
Output voltageX,XV

Nameplate output voltage. Shall indicate whether is AC or DC.

In cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be published.

Output currentX,XA

Nameplate output current.

In cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be published.

Output powerX,XW

Nameplate output power.

In cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be published.

Average active efficiencyX,X%

Declared by the manufacturer based on the value calculated as arithmetical mean of efficiency at load conditions 1-4.

In cases where multiple average active efficiencies are declared for multiple output voltages available at load condition 1, the value published shall be the average active efficiency declared for the lowest output voltage.

Efficiency at low load (10 %)X,X%

Declared by the manufacturer based on the value calculated at load condition 5.

External power supplies with a nameplate output power of 10 W or less shall be exempted from this requirement.

In cases where multiple average active efficiencies are declared for multiple output voltages available at load condition 1, the value published shall be the value declared for the lowest output voltage.

No-load power consumptionX,XXWDeclared by the manufacturer based on the value measured for load condition 6.

The relevant load conditions are as follows:

Percentage of nameplate output current
Load condition 1100 % ± 2 %
Load condition 275 % ± 2 %
Load condition 350 % ± 2 %
Load condition 425 % ± 2 %
Load condition 510 % ± 1 %
Load condition 60 % (no-load condition)
(c)

from 1 April 2020, the technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:

(1)

for external power supplies with a nameplate output power greater than 10 watts:

Reported QuantityDescription
Root mean square output current (mA)Measured at load conditions 1-5
Root mean square output voltage (V)
Active output power (W)
Root mean square input voltage (V)Measured at load conditions 1-6
Root mean square input power (W)
Total harmonic distortion of the input current
True power factor
Power consumed (W)Calculated at load conditions 1-5, measured at load condition 6
Active mode efficiencyCalculated at load conditions 1-5
Average active efficiencyArithmetical mean of efficiency at load conditions 1-4

In cases where more than one physical output or more than one output voltage at load condition 1 are measured, the relevant reported quantities shall be specified for each measurement.

The relevant load conditions are set out in point 2(b);

(2)

for external power supplies with a nameplate output power of 10 watts or less:

Reported QuantityDescription
Root mean square output current (mA)Measured at load conditions 1-4
Root mean square output voltage (V)
Active output power (W)
Root mean square input voltage (V)Measured at load conditions 1-4 and 6
Root mean square input power (W)
Total harmonic distortion of the input current
True power factor
Power consumed (W)Calculated at load conditions 1-4, measured at load condition 6
Active mode efficiencyCalculated at load conditions 1-4
Average active efficiencyArithmetical mean of efficiency at load conditions 1-4

In cases where more than one physical output or more than one output voltage at load condition 1 are measured, the relevant reported quantities shall be specified for each measurement.

The relevant load conditions are set out in point 2(b).

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources