Commission Regulation (EU) 2019/1782Show full title

Commission Regulation (EU) 2019/1782 of 1 October 2019 laying down ecodesign requirements for external power supplies pursuant to Directive 2009/125/EC of the European Parliament and of the Council and repealing Commission Regulation (EC) No 278/2009 (Text with EEA relevance)

ANNEX IIU.K. Ecodesign requirements for external power supplies

1.Energy efficiency requirements:U.K.

(a)

from 1 April 2020, the no-load condition power consumption shall not exceed the following values:

AC-AC external power supplies, except low voltage and multiple voltage output external power suppliesAC-DC external power supplies, except low voltage and multiple voltage output external power suppliesLow voltage external power suppliesMultiple voltage output external power supplies
PO ≤ 49,0 W0,21 W0,10 W0,10 W0,30 W
PO > 49,0 W0,21 W0,21 W0,21 W0,30 W
(b)

from 1 April 2020, the average active efficiency shall be not less than the following values:

AC-AC external power supplies, except low voltage and multiple voltage output external power suppliesAC-DC external power supplies, except low voltage and multiple voltage output external power suppliesLow voltage external power suppliesMultiple voltage output external power supplies
PO ≤ 1,0 W0,5 × PO/1W+ 0,1600,5 × PO/1W+ 0,1600,517 × PO/1W+ 0,0870,497 × PO/1W+ 0,067
1 W < PO ≤ 49,0 W0,071 × ln(PO/1W) – 0,0014 × PO/1W+ 0,670,071 × ln(PO/1W) – 0,0014 × PO/1W+ 0,670,0834 × ln(PO/1W) – 0,0014 × Po/1W+ 0,6090,075 × ln(PO/1W) + 0,561
PO > 49,0 W0,8800,8800,8700,860

2.Information requirements:U.K.

(a)

from 1 April 2020, the nameplate shall include the following information:

Nameplate informationValue and precisionUnitNotes
Output powerX,XWIn cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be given.
Output voltageX,XVIn cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be given.
Output currentX,XAIn cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be given.
(b)

from 1 April 2020, instruction manuals for end-users (where applicable), and free access websites of manufacturers, importers or authorised representatives shall include the following information, in the order as set out below:

Information publishedValue and precisionUnitNotes
Manufacturer’s name or trade mark, commercial registration number and address---
Model identifier---
Input voltageXVSpecified by the manufacturer. Shall be a value or a range.
Input AC frequencyXHzSpecified by the manufacturer. Shall be a value or a range.
Output voltageX,XV

Nameplate output voltage. Shall indicate whether is AC or DC.

In cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be published.

Output currentX,XA

Nameplate output current.

In cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be published.

Output powerX,XW

Nameplate output power.

In cases where more than one physical output or more than one output voltage at load condition 1 are measured, the sets of available Output voltage — Output current – Output power shall be published.

Average active efficiencyX,X%

Declared by the manufacturer based on the value calculated as arithmetical mean of efficiency at load conditions 1-4.

In cases where multiple average active efficiencies are declared for multiple output voltages available at load condition 1, the value published shall be the average active efficiency declared for the lowest output voltage.

Efficiency at low load (10 %)X,X%

Declared by the manufacturer based on the value calculated at load condition 5.

External power supplies with a nameplate output power of 10 W or less shall be exempted from this requirement.

In cases where multiple average active efficiencies are declared for multiple output voltages available at load condition 1, the value published shall be the value declared for the lowest output voltage.

No-load power consumptionX,XXWDeclared by the manufacturer based on the value measured for load condition 6.

The relevant load conditions are as follows:

Percentage of nameplate output current
Load condition 1100 % ± 2 %
Load condition 275 % ± 2 %
Load condition 350 % ± 2 %
Load condition 425 % ± 2 %
Load condition 510 % ± 1 %
Load condition 60 % (no-load condition)
(c)

from 1 April 2020, the technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:

(1)

for external power supplies with a nameplate output power greater than 10 watts:

Reported QuantityDescription
Root mean square output current (mA)Measured at load conditions 1-5
Root mean square output voltage (V)
Active output power (W)
Root mean square input voltage (V)Measured at load conditions 1-6
Root mean square input power (W)
Total harmonic distortion of the input current
True power factor
Power consumed (W)Calculated at load conditions 1-5, measured at load condition 6
Active mode efficiencyCalculated at load conditions 1-5
Average active efficiencyArithmetical mean of efficiency at load conditions 1-4

In cases where more than one physical output or more than one output voltage at load condition 1 are measured, the relevant reported quantities shall be specified for each measurement.

The relevant load conditions are set out in point 2(b);

(2)

for external power supplies with a nameplate output power of 10 watts or less:

Reported QuantityDescription
Root mean square output current (mA)Measured at load conditions 1-4
Root mean square output voltage (V)
Active output power (W)
Root mean square input voltage (V)Measured at load conditions 1-4 and 6
Root mean square input power (W)
Total harmonic distortion of the input current
True power factor
Power consumed (W)Calculated at load conditions 1-4, measured at load condition 6
Active mode efficiencyCalculated at load conditions 1-4
Average active efficiencyArithmetical mean of efficiency at load conditions 1-4

In cases where more than one physical output or more than one output voltage at load condition 1 are measured, the relevant reported quantities shall be specified for each measurement.

The relevant load conditions are set out in point 2(b).

3.Measurements and calculationsU.K.

For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements and calculations shall be made using [F1designated standards], or other reliable, accurate and reproducible methods, which take into account the generally recognised state of the art.