At the time of entry into force of this Regulation, the best available technology on the market for external power supplies in terms of their no-load power consumption and average active efficiency was identified as follows:
No-load condition:
The lowest available no-load condition power consumption of external power supplies can be approximated as:
0,002 watt, for PO ≤ 49,0 watts,
0,010 watt, for PO > 49,0 watts.
Average active efficiency:
The best available active average efficiency of external power supplies can be approximated as:
0,767, for PO ≤ 1,0 watt,
0,905, for 1,0 watt < PO ≤ 49,0 watts,