ANNEX IVBenchmarks

At the time of entry into force of this Regulation, the best available technology on the market for external power supplies in terms of their no-load power consumption and average active efficiency was identified as follows:

  1. (a)

    No-load condition:

    The lowest available no-load condition power consumption of external power supplies can be approximated as:

    • 0,002 watt, for PO ≤ 49,0 watts,

    • 0,010 watt, for PO > 49,0 watts.

  2. (b)

    Average active efficiency:

    The best available active average efficiency of external power supplies can be approximated as:

    • 0,767, for PO ≤ 1,0 watt,

    • 0,905, for 1,0 watt < PO ≤ 49,0 watts,

    • 0,962, for PO > 49,0 watts.