ANNEX IVU.K. Benchmarks

At the time of entry into force of this Regulation, the best available technology on the market for external power supplies in terms of their no-load power consumption and average active efficiency was identified as follows:

(a)

No-load condition:

The lowest available no-load condition power consumption of external power supplies can be approximated as:

  • 0,002 watt, for PO ≤ 49,0 watts,

  • 0,010 watt, for PO > 49,0 watts.

(b)

Average active efficiency:

The best available active average efficiency of external power supplies can be approximated as:

  • 0,767, for PO ≤ 1,0 watt,

  • 0,905, for 1,0 watt < PO ≤ 49,0 watts,

  • 0,962, for PO > 49,0 watts.