xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"

ANNEX IIU.K.

A.Energy efficiency classesU.K.

The energy efficiency class of an electronic display shall be determined on the basis of its energy efficiency index for labelling (EEIlabel ) as set out in Table 1. The EEIlabel of an electronic display shall be determined in accordance with part B of this Annex.

Table 1

Energy efficiency classes of electronic displays

Energy Efficiency ClassEnergy Efficiency Index (EEIlabel )
A EEIlabel < 0,3
B0,3 ≤ EEIlabel < 0,4
C0,4 ≤ EEIlabel < 0,5
D0,5 ≤ EEIlabel < 0,6
E0,6 ≤ EEIlabel < 0,75
F0,75 ≤ EEIlabel < 0,9
G0,9 ≤ EEIlabel

B.Energy Efficiency Index (EEIlabel )U.K.

The Energy Efficiency Index (EEIlabel ) of the electronic display shall be calculated using the following equation:

where:

A represents the viewing surface area in dm2;

Pmeasured is the measured power in on mode in Watts in the normal configuration and set as indicated in Table 2;

corrl is a correction factor set as indicated in Table 3.

Table 2

Measurement of Pmeasured

Dynamic Range levelPmeasured
Standard Dynamic Range (SDR): PmeasuredSDR Power demand in Watts (W) in on mode, measured when displaying standardised test sequences of moving picture from dynamic broadcast content. Where allowances are applicable according to part C of this Annex, they should be deducted from Pmeasured .

High Dynamic Range (HDR)

PmeasuredHDR

Power demand in Watts (W) in on mode, measured as for PmeasuredSDR but with the HDR functionality activated by metadata in the standardised HDR test sequences. Where allowances are applicable according to part C of this Annex, they should be deducted from Pmeasured .

Table 3

corrl value

Electronic Display type corrl value
Television0,0
Monitor0,0
Digital signage

0,00062*(lum-500)*A

where ‘lum’ is the peak white luminance, in cd/m2, of the brightest on mode configuration of the electronic display and A is the screen area in dm2

C.Allowances and adjustments for the purpose of the EEIlabel calculationU.K.

Electronic displays with automatic brightness control (ABC) shall qualify for a 10 % reduction in Pmeasured if they meet all of the following requirements:

(a)

ABC is enabled in the normal configuration of the electronic display and persists in any other standard dynamic range configuration available to the end user;

(b)

the value of Pmeasured , in the normal configuration, is measured, with ABC disabled or if ABC cannot be disabled, in an ambient light condition of 100 lux measured at the ABC sensor;

(c)

if applicable, the value of Pmeasured with ABC disabled shall be equal to or greater than the on mode power measured with ABC enabled in an ambient light condition of 100 lux measured at the ABC sensor;

(d)

with ABC enabled, the measured value of the on mode power must decrease by 20 % or more when the ambient light condition, measured at the ABC sensor, is reduced from 100 lux to 12 lux;

(e)

the ABC control of the display screen luminance meets all of the following characteristics when the ambient light condition measured at the ABC sensor changes:

  • the measured screen luminance at 60 lux is between 65 % and 95 % of the screen luminance measured at 100 lux;

  • the measured screen luminance at 35 lux is between 50 % and 80 % of the screen luminance measured at 100 lux;

  • the measured screen luminance at 12 lux is between 35 % and 70 % of the screen luminance measured at 100 lux.