C1ANNEX IVMeasurement methods and calculations
Annotations:
Modifications etc. (not altering text)
9.LOW POWER MODES
The power consumption of the off mode (Po), standby mode (Psm) and where applicable delay start (Pds) are measured. The measured values are expressed in W and rounded to two decimal places.
During measurement of the power consumption in low power modes, the following shall be checked and recorded:
the display or not of information;
the activation or not of a network connection.
If a household washing machine or a household washer-dryer provides for a wrinkle guard function, this operation shall be interrupted by opening the household washing machine or household washer-dryer door, or any other appropriate intervention 15 minutes before the measurement of energy consumption.
Annexes 1-5 applied (with modifications) (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2020 (S.I. 2020/1528), regs. 1(4), 30(1)-(3), Sch. 2