Please note that the date you requested in the address for this web page is not an actual date upon which a change occurred to this item of legislation. You are being shown the legislation from , which is the first date before then upon which a change was made.
From 1 September 2021, the functional requirements specified in Table 4 shall apply for light sources:
Functional requirements for light sources
Colour rendering | CRI ≥ 80 (except for HID with Φuse > 4 klm and for light sources intended for use in outdoor applications, industrial applications or other applications where lighting standards allow a CRI< 80, when a clear indication to this effect is shown on the light source packaging and in all relevant printed and electronic documentation) |
Displacement factor (DF, cos φ1) at power input Pon for LED and OLED MLS | No limit at Pon ≤ 5 W, DF ≥ 0,5 at 5 W < Pon ≤ 10 W, DF ≥ 0,7 at 10 W < Pon ≤ 25 W DF ≥ 0,9 at 25 W < Pon |
Lumen maintenance factor (for LED and OLED) | The lumen maintenance factor XLMF% after endurance testing according to Annex V shall be at least XLMF,MIN % calculated as follows: where L70 is the declared L70B50 lifetime (in hours) If the calculated value for XLMF,MIN exceeds 96,0 %, an XLMF,MIN value of 96,0 % shall be used |
Survival factor (for LED and OLED) | Light sources should be operational as specified in row ‘Survival factor (for LED and OLED)’ of Annex IV, Table 6, following the endurance testing given in Annex V. |
Colour consistency for LED and OLED light sources | Variation of chromaticity coordinates within a six-step MacAdam ellipse or less. |
Flicker for LED and OLED MLS | Pst LM ≤ 1,0 at full-load |
Stroboscopic effect for LED and OLED MLS | SVM ≤ 0,4 at full-load (except for HID with Φuse > 4 klm and for light sources intended for use in outdoor applications, industrial applications or other applications where lighting standards allow a CRI< 80) |