Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
27.—(1) The amount of heat in kWh which an accredited domestic plant is deemed to generate every 12 months (the “deemed annual heat generation”) is calculated in accordance with this regulation.
(2) If the accredited domestic plant is a biomass plant which provides space heating (but not heating for domestic hot water) to the RHI property, the deemed annual heat generation is the heat demand for space heating specified in the relevant EPC for that property.
(3) If the accredited domestic plant is a biomass plant which provides both space heating and domestic hot water heating to the RHI property, the deemed annual heat generation is the heat demand for space heating and water heating specified in the relevant EPC for that property.
(4) If the accredited domestic plant is a heat pump which provides space heating (but not heating for domestic hot water) to the RHI property, the deemed annual heat generation is calculated in accordance with the following formula—
where—
A is the heat demand for space heating specified in the relevant EPC for that property;
B is the seasonal performance factor for the heat pump.
(5) If the accredited domestic plant is a heat pump which provides both space heating and domestic hot water heating to the RHI property, the deemed annual heat generation is calculated in accordance with the following formula—
where—
A is the heat demand for space heating and water heating specified in the relevant EPC for that property;
B is the seasonal performance factor for the heat pump.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: