1. The requirements which have to be satisfied in relation to a silo are that—
(a)it complies with paragraphs 2 to 9; or
(b)if it is designed and constructed, before 20th August 2013, in accordance with the standard on cylindrical forage tower silos published by the British Standards Institution and numbered BS 5061: 1974(1).
2. The base of the silo shall, where the silo has retaining walls made other than of earth, extend beyond those walls and shall in all cases be provided with channels so constructed as to collect any silage effluent which may escape from the silo and adequate provision shall be made for the drainage of that effluent from the channels to an effluent tank through a channel or pipe.
3.—(1) Subject to sub-paragraph (2), the capacity of the effluent tank—
(a)in the case of a silo with a capacity of less than 1500 cubic metres, shall be not less than 3 cubic metres for each 150 cubic metres or part thereof of silo capacity;
(b)in the case of a silo with a capacity of 1500 cubic metres or more, shall be not less than 30 cubic metres plus one cubic metre for each 150 cubic metres or part thereof of silo capacity in excess of 1500 cubic metres.
(2) The effluent collection system associated with silos may, with the agreement of the Department, incorporate a system of pumps and sumps, together with detailed sizing, pumping and management requirements, designed to reduce the capacity of the effluent tank.
4. The base of the silo, the base and walls of its effluent tank and channels and the walls of any pipes shall be impermeable.
5. The base and any walls of the silo, its effluent tank and channels and the walls of any pipes shall, so far as reasonably practicable, be resistant to attack by silage effluent and, where the walls are made of earth, they shall be lined with an impermeable membrane.
6. No part of the silo, its effluent tank or channels or any associated pipes shall be situated within 10 metres of any waterway into which silage effluent could enter if it were to escape.
7. If the silo has retaining walls—
(a)the retaining walls shall be capable of withstanding minimum wall loadings calculated on the assumptions and in the manner indicated by paragraph 15.6.1 to 15.6.3 of the Code of Practice on Buildings and Structures for Agriculture published by the British Standards Institution and numbered BS 5502-22:2003+A1:2013(2);
(b)the silo shall at no time be loaded to a depth exceeding the maximum depth consistent with the design assumption made in respect of the loadings of the retaining walls; and
(c)notices shall be displayed on the retaining walls in accordance with paragraph 18 of the Code of Practice referred to in sub-paragraph (a).
8. Subject to paragraph 9, the silo, its effluent tank and channels and any pipes shall be designed and constructed so that with proper maintenance they are likely to satisfy the requirements of paragraphs 2 to 5 and, if applicable, 7(a) for a period of at least 20 years.
9. Where any part of an effluent tank is installed below ground level, it shall be designed and constructed in accordance with the Code of Practice referred to in paragraph 7(a) so that with proper maintenance it is likely to satisfy the requirements of paragraphs 4 and 5 for a period of at least 20 years.
Publication date: 11th April 1974. ISBN 0-580-08070-6.
Publication date: 10th June 2003. ISBN 978-0-580-78768-3.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Rule and provides information about its policy objective and policy implications. They aim to make the Statutory Rule accessible to readers who are not legally qualified and accompany any Northern Ireland Statutory Rule or Draft Northern Ireland Statutory Rule laid before the UK Parliament during the suspension of the Northern Ireland Assembly.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: