- Latest available (Revised)
- Point in Time (27/03/2011)
- Original (As made)
Version Superseded: 28/02/2019
Point in time view as at 27/03/2011. This version of this provision has been superseded.
You are viewing this legislation item as it stood at a particular point in time. A later version of this or provision, including subsequent changes and effects, supersedes this version.
Note the term provision is used to describe a definable element in a piece of legislation that has legislative effect – such as a Part, Chapter or section.
There are currently no known outstanding effects for the The Landfill (Scotland) Regulations 2003, Paragraph 3.
Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
3.—(1) The landfill must be situated and designed so as to –
(a)provide the conditions for prevention of pollution of the soil, groundwater or surface water; and
(b)ensure efficient collection of leachate as and when required by paragraph 2.
(2) Soil, groundwater and surface water is to be protected by the use of a geological barrier combined with–
(a)a bottom liner during the operational phase of the landfill; and
(b)a top liner following closure and during the after-care phase.
(3) The geological barrier shall comply with the requirements of sub-paragraph (4) and shall also provide sufficient attenuation capacity to prevent a potential risk to soil and groundwater.
(4) The landfill base and sides shall consist of a mineral layer which provides protection of soil, groundwater and surface water at least equivalent to that resulting from the following permeability and thickness requirements–
(a)in a landfill for hazardous waste: K �?� 1.0 × 10-9 metre/second: thickness �?� 5 metres;
(b)in a landfill for non-hazardous waste: K �?� 1.0 × 10-9 metre/second: thickness �?� 1 metre;
(c)in a landfill for inert waste: K �?� 1.0 × 10-7 metre/second: thickness �?� 1 metre.
(5) Where the geological barrier does not meet the requirements of sub-paragraph (4) naturally, it may be completed artificially and reinforced by other means giving equivalent protection, but in any such case a geological barrier established by artificial means must be at least 0.5 metres thick.
(6) A leachate collection and sealing system to ensure that leachate accumulation at the base of the landfill is kept to a minimum must also be provided in any hazardous or non-hazardous landfill in accordance with the following table:
Landfill category | Non-hazardous | Hazardous |
---|---|---|
Artificial sealing liner | Required | Required |
Drainage liner �?� 0.5 metres | Required | Required |
(7) Where the potential hazards to the environment indicate that the prevention of leachate formation is necessary, surface sealing may be required taking account of the following guidelines:–
Landfill category | Non-hazardous | Hazardous |
---|---|---|
Gas drainage layer | Required | Not required |
Artificial sealing liner | Not required | Required |
Impermeable mineral layer | Required | Required |
Drainage layer > 0.5 metres | Required | Required |
Top soil cover > 1 metre | Required | Required |
(8) The requirements of sub-paragraphs (3) to (7) may be reduced to an appropriate extent if on the basis of an assessment of environmental risks, having regard in particular to Directive 80/68/EEC M1–
(a)it has been decided in accordance with paragraph 2 that the collection and treatment of leachate is not necessary; or
(b)it is established that the landfill poses no potential hazard to soil, groundwater or surface water.
Marginal Citations
M1O.J. No. L 20, 26.1.80, p.43 as amended by Directive 91/692/EEC O.J. No. L 377, 31.12.91, p.48.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: