Approved measuring devices – underlying level of noise5.

(1)

For the purposes of section 49(1) of the Act (approval of measuring devices), subject to paragraph (2), sound level meters which:

(a)

comply with the requirements of Class 1 of BS EN 61672; and

(b)

are capable of determining the A-weighted sound pressure level using time-weighting ‘F’,

are devices approved for the measurement of the underlying level of noise, when used in accordance with the requirements of regulations 7 and 8.

(2)

Where LAN,T measurements are used to determine the underlying level of noise, the devices specified in paragraph (1) must in addition:

(a)

sample the sound pressure level at a rate of not less than 10 times per second; and

(b)

use in the statistical calculation a class interval of no greater than 0.5 decibels.

(3)

When time weighting ‘F’ is used for the purposes of paragraph (1) it shall not exceed 0.6 seconds in a period of no shorter than one minute and no longer than 5 minutes.