SCHEDULE 1
The limits of field strength and terminal voltage shall be as follows:
Col. 1 | Col. 2 | Col. 3 | Col. 4 | Col. 5 | |
---|---|---|---|---|---|
Frequency Range in MHz | Maximum radiated field strength in microvolts per metre | Maximum terminal voltage in microvolts per metre | For protection of safety of life services | ||
Exceeding | Not Exceeding |
|
| Maximum radiated field strength in microvolts per metre | Maximum terminal voltage in microvolts |
13·533 | 13·553 | 300,000 | 5,000,000 |
|
|
13·553 | 13·567 | unlimited | unlimited |
|
|
13·567 | 13·587 | 300,000 | 5,000,000 |
|
|
26·957 | 27·283 | unlimited | unlimited |
|
|
83·996 | 84·004 | 3,000,000 |
|
|
|
167·992 | 168·008 | 3,000,000 |
|
|
|
886 | 906 | 1,000,000 |
|
|
|
For all other frequencies in the ranges specified below, the limits of field strength and terminal voltage shall be as follows:
Col. 1 | Col. 2 | Col. 3 | Col. 4 | Col. 5 | |
---|---|---|---|---|---|
0·15 | 0·2 | 50 | 3,000 | 15 | 1,000 |
0·2 | 0·285 | 50 | 2,000 | 15 | 650 |
0·285 | 0·49 | 250 | 2,000 | 80 | 650 |
0·49 | 0·5 | 50 | 2,000 | 15 | 650 |
0·5 | 1·605 | 50 | 1,000 | 15 | 350 |
1·605 | 3·95 | 250 | 1,000 | 80 | 350 |
3·95 | 30·00 | 50 | 1,000 | 15 | 350 |
30·00 | 470·00 | 30 |
| 10 |
|
470·00 | 1,000·00 | 100 |
| 35 |
|