Regulation 5
Voltage and e.m.f.
References to the voltage or e.m.f. of a sinewave are references to its effective or root mean square value.
Decibel (abbreviated dB)
A unit of transmission giving the ratio of two powers.
If P1 and P2 represent two values of power, and n the number of decibels representing their ratio:
No math image to display
If the two powers are dissipated in equal resistive impedances, their ratio in decibels may be expressed by:
No math image to display
V1, V2 are the voltages across the two resistive impedances.
Terminal voltage calibration constant
The number of decibels that must be added to the reading of the measuring apparatus, when a measurement of terminal voltage is made as prescribed, to give the terminal voltage in decibels above 1 microvolt.
Field strength calibration constant
The number of decibels that must be added to the reading of the measuring apparatus, when a measurement of field-strength is made as prescribed, to give the value of field-strength in decibels above 1 microvolt per metre.
1. Where a radio-frequency heating apparatus is being tested for the purpose of this regulation it shall so far as is consistent with the following provisions of this Part of this Schedule, be tested under its normal conditions of installation.
2. The radio-frequency heating apparatus must be tested in complete working form with its work circuit connected. The load employed for the test shall be similar to that which was being treated at the time of the alleged interference, and the electrodes and cables shall be disposed in the manner of their normal use.
3. All other electrical apparatus which is installed in proximity to the radio-frequency heating apparatus, and which in operation could appreciably affect the result of the test, shall be switched off or otherwise prevented from being energised by complete or partial electrical disconnection.
4. The measuring set receiver shall be connected with an appropriate source of electric power. The receiver shall be tuned to the frequency, as indicated by the tuning dial calibrations, at which it is desired to test, and its gain shall be set, in accordance with the relevant instruction manual, to that used when the measuring set was calibrated.
5.—(1) The receiver shall be connected to the aerial mentioned in British Standard 727 : 1967 clause 11.1.2, page 13 or the aerial and feeder mentioned in British Standard 727 : 1967 clause 11.2.1 page 13 (as the case may be).
(2) The distance between the aerial of the measuring apparatus and the nearest point on the boundary of the premises in which the radio-frequency heating apparatus is installed shall not be greater than 100 metres for measurement in the frequency range 0.15 megahertz up to and including 30 megahertz, and 30 metres for higher frequencies up to and including 1000 megahertz.
(3) For the frequency range 0–15 megahertz up to and including 30 megahertz the aerial shall be supported in a vertical plane and be rotatable about a vertical axis. The lowest point of the loop shall be 1 metre above the ground.
(4) For higher frequencies up to and including 1000 megahertz the centre of the aerial shall be supported at a height of not less than 2.8 metres and not more than 3.2 metres above the ground. Measurements shall be made in each case with the measuring aerial horizontal and vertical. When the aerial is used in the horizontal plane it shall be orientated in that plane for maximum output on the measuring set.
6. For the purpose of the main test in paragraph 8 of this Part of this Schedule the radio-frequency heating apparatus shall be switched on, and adjusted to deliver its rated output power into the work load.
7.—(1) The measuring receiver shall be adjusted and operated in accordance with the relevant instruction manual. The field-strength shall be observed over the whole of the work cycle of the radio-frequency heating apparatus and the highest value, subject to the provisions of paragraph 9 of this Part of this Schedule, shall be taken.
(2) The frequency at which a test is being made shall be measured by means of a frequency meter incorporating a crystal controlled frequency standard having an inherent error of measurement not greater than one part in one hundred thousand.
The frequency shall be measured over the load range from the lowest power normally used to maximum power.
8. A set of tests shall be made in each case as follows:
(a)A check test while the radio-frequency heating apparatus is not operating;
(b)A main test;
(c)A further check test as mentioned in (a).
9. If a click (as opposed to a buzz of appreciable duration) is heard in the monitoring loudspeaker or earphones at any time when any switchgear or controlling apparatus of the radio-frequency heating apparatus is operating, then provided that not more than one further click is heard during the period of two seconds immediately following the first, the readings of the measuring apparatus appearing within that period of two seconds shall be disregarded for the purpose of these Regulations.
10. The field-strength expressed in decibels above 1 microvolt per metre will be given by the sum of: (a) the reading(s) of the attenuator(s), (b) the field-strength calibration constant (if any) appropriate to the frequency at which the measurement is being made, and (c) the reading of the indicating meter of the valve-voltmeter, if calibrated in decibels. If the result obtained is x decibels, the field strength expressed in microvolts per metre is given by the antilog to the base 10 of x/20
11. If the maximum reading obtained on any main test exceeds the maximum reading obtained on either of the check tests made next before or next after that main test by at least 10 dB, the readings obtained on that main test are to be regarded as not materially affected by extraneous noise or signals. Otherwise the readings obtained on that main test are to be regarded as materially affected by extraneous noise or signals, and the results of that main test shall be disregarded for the purpose of these Regulations.
1.—(1) Where a radio-frequency heating apparatus is being tested for the purpose of this regulation, it shall be connected with an appropriate source of electric power.
(2) The radio-frequency heating apparatus shall be tested under its normal conditions of installation with a work load similar to that being treated at the time of the complaint.
(3) The measurement of terminal voltage shall be made at any convenient point within the boundaries of the user's premises but as near to the boundary as practicable.
2. The following connexions shall be made:
The electric supply line terminal of the radio-frequency heating apparatus which is the terminal being tested shall be connected through the isolation capacitor C and the 1450 ohm resistor shown in Fig. 1. An inductor L shall be connected between the input terminal of the measuring set and the screening of the measuring set.
The impedance of the capacitor C at the frequency of measurement shall be less than 10 ohms. The impedance of the inductor L at the frequency of measurement shall be greater than 1000 ohms.
3. A set of tests as mentioned in sub-paragraphs (a), (b) and (c) of paragraph 8 of Part 2 of this Schedule shall be made in each case with the receiver of the testing apparatus connected with one of the electric supply line terminals of the radio-frequency heating apparatus and another set or other sets of tests as mentioned in those sub-paragraphs shall be made with the receiver of the testing apparatus connected with the other or each of the others of such terminals.
4. Paragraph 9 of Part 2 of this Schedule shall apply.
5. The terminal voltage, expressed in decibels above 1 microvolt, will be given by the sum of: (a) the reading(s) of the attenuator(s), (b) the terminal voltage calibration constant (if any) appropriate to the frequency at which the measurement is being made, (c) the reading of the indicating meter of the valve-voltmeter, if calibrated in decibels and (d) 30 decibels to take into account the loss in the measuring circuit shown in Fig. 1. If the result obtained is x decibels, the voltage expressed in microvolts is given by the antilog to the base 10 of x/20.
6. Paragraph 11 of Part 2 of this Schedule shall apply.