Search Legislation

The Merchant Shipping (Crew Accommodation) (Fishing Vessels) Regulations 1975

 Help about what version

What Version

  • Latest available (Revised)
  • Original (As made)

Status:

This is the original version (as it was originally made). This item of legislation is currently only available in its original format. The electronic version of this UK Statutory Instrument has been contributed by Westlaw and is taken from the printed publication. Read more

Ventilation

16.—(1) Every enclosed space in the crew accommodation, except a cold store room, shall be provided with a ventilation system capable of maintaining the air in that space in a sufficiently pure condition for the health and comfort of the crew in all the conditions of weather and climate which the vessel is likely to encounter during the voyages on which she is intended to be engaged, and capable of being controlled as necessary for that purpose. The ventilation system shall be additional to any sidescuttles, skylights, companionways, doors or other openings not intended solely for ventilation, and shall be so arranged as to keep noise levels to a minimum and not to cause undue vibration.

(2) The ventilation system provided for an enclosed space may be either a natural system of inlet and exhaust ventilation or a trunked mechanical ventilation system, except in vessels for the time being regularly engaged in voyages to or in the Tropics or the Persian Gulf which shall be provided with a trunked mechanical ventilation system.

(3) If a natural ventilation system is provided, it shall comply with the following requirements:

(a)Every inlet ventilator which is situated in the open air shall be of a cowl or other equally efficient type and shall be so placed that, so far as is practicable, it is not screened from the wind in any direction. No inlet ventilator shall be situated over a doorway, stairway or exhaust opening.

(b)The sectional area of all parts of the inlet and exhaust system, except parts serving a drying room or locker only, shall be at least 0·012 square metres in all or at least 0·004 square metres per person for as many persons as are likely to use the room at any one time, whichever shall be the greater. The effective area of the inlet and exhaust system serving each space shall be adjustable from fully open down to a minimum area of 0·002 square metres per person for as many persons as are likely to use the room at any one time.

(4) If a trunked mechanical ventilation system is fitted, it shall so far as is reasonably practicable comply with the requirements specified in Schedule 3 to these Regulations provided that:

(a)vessels for the time being regularly engaged in voyages in the Tropics or the Persian Gulf shall comply fully with those requirements; and

(b)in vessels employed solely within the home trade limits, the number of fresh air changes specified in that Schedule may be reduced by one third.

(5) In vessels other than those regularly engaged on voyages:

(i)within home trade limits;

(ii)round the coasts of New Zealand;

(iii)north of latitude 53° North; or

(iv)south of latitude 45° South;

a suitable electric fan shall be fitted in every sleeping room, messroom, hospital, galley and pantry which is not served by a trunked mechanical ventilation system.

(6) The following spare gear, properly packed for storage, shall be carried for any trunked mechanical ventilation system or fans fitted in compliance with this regulation:

(a)for each size of motor fitted, 1 set of bearings;

(b)for each size of starter fitted:

(i)1 set of contacts,

(ii)1 set of springs, and

(iii)1 operating coil.

(7) A supply of power adequate to operate any trunked mechanical ventilation system or fans shall be provided. Any such system or fans, as the case may be, shall be in operation at all times when any members of the crew are on board and the circumstances are such that ventilation by means of such system or fans is required.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources