I1SCHEDULE 2

Annotations:
Commencement Information
I1

Sch. 2 in force at 1.11.1988, see reg. 1(2)(a)

PART IV

Ignitability test for composite fillings of mattresses and bed-bases.

1

The test specimen shall be prepared as set out in BS 6807. It may be constructed from the filling materials to be used or by removing existing ticking from a mattress or upholstered divan or bed-base.

2

The specified test fabric as in Schedule 1 Part I paragraph 2, shall be used as the cover fabric. It shall be fitted so as to reproduce the tension in the original article where this is being tested.

3

The test shall be carried out according to Section Four of BS 6807 using ignition source 2 as specified in BS 5852: Part 2. Smouldering or flaming failure shall be as defined in BS 5852: Part 2.