- Latest available (Revised)
- Original (As made)
This is the original version (as it was originally made). This item of legislation is currently only available in its original format.
Regulation 10
1. If the efficiency of a boiler at rated output and its efficiency at part load are equal to or greater than the relevant values for standard boilers, the boiler may be labelled with a single star as set out in Part II of this Schedule.
2. If the efficiency of a boiler at rated output and its efficiency at part load are three or more points higher than the relevant value for standard boilers, the boiler may be labelled with two stars as set out in Part III of this Schedule.
3. Every extra step of efficiency of three points at rated output and at part load will allow the attribution of an extra star as set out in Part III of this Schedule.
Label | Efficiency requirement at nominal output Pn and at an average boiler-water temperature of 70°C % | Efficiency requirement at part load of 0.3 Pn and at an average boiler-water temperature of ≥50°C % |
---|---|---|
★ | ≥84 + 2 log Pn | ≥80 + 3 log Pn |
★★ | ≥87 + 2 log Pn | ≥83 + 3 log Pn |
★★★ | ≥90 + 2 log Pn | ≥86 + 3 log Pn |
★★★★ | ≥93 + 2 log Pn | ≥89 + 3 log Pn |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include: