55.—(1) Every overboard scupper, sanitary discharge or other inlet or outlet installed in a location where the failure of any such inlet or outlet could cause flooding in the event of fire shall be constructed of materials that are not readily rendered ineffective by heat.
(2) Pipes intended to convey oil or other flammable liquids shall be of a suitable material having regard to risk of fire. Such pipes shall not be installed in accommodation and service spaces unless adequate precautions are taken having regard to the risk of fire and the Certifying Authority considers their installation necessary.
(3) The surface of any insulation shall be impervious to oil or oil vapours in any space where the penetration of oil or oil products would otherwise be possible.
(4) Asbestos or any material containing asbestos shall not be installed in any part of the ship except that white asbestos may be used in machinery when a substitute material is not available.