Machinery spaces containing steam turbines or enclosed steam engines

8.—(1) In every ship of Class I there shall be provided in spaces containing steam turbines or enclosed pressure-lubricated steam engines used either for main propulsion, or having in the aggregate a total power of not less than 375 kW for auxiliary purposes—

(a)foam fire extinguishers each of at least 45 litres capacity or carbon dioxide fire extinguishers each of at least 16 kilogrammes capacity sufficient in number to enable foam or carbon dioxide to be directed on to any part of the pressure lubrication system and on to any part of the casings enclosing pressure lubricated parts of the turbine, engines or associated gearing and any other areas of high fire risk; provided that such extinguishers shall not be required if equivalent protection is provided in such spaces by a fixed fire-extinguishing system fitted in compliance with regulation 7(1);

(b)portable fire extinguishers suitable for extinguishing oil fires sufficient in number to ensure that at least one extinguisher is not more than 10 metres walking distance from any position within the space: provided that there shall be not less than two such extinguishers;