Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
60.—(1) Electrical equipment shall not be installed in any hazardous area unless such equipment is—
(a)essential for operational or safety purposes;
(b)of a type that is certified for use in the flammable dusts, gases or vapours to which it may be subjected; and
(c)appropriate to the space concerned.
(2) Cables passing through any hazardous areas or serving electrical equipment in such areas shall—
(a)be appropriate having regard to the dusts, gases or vapours to which they may be subjected; and
(b)unless they form part of intrinsically safe circuits be enclosed in a gas-tight steel conduit or include a metallic sheath braid or wire armour for earth leakage detection or be protected in some other satisfactory manner. Additional protection against mechanical damage shall be provided in locations where such damage may occur.
(3) In special category spaces the electrical equipment shall be certified for use in explosive petrol and air mixtures and the cables shall be appropriate for use in such mixtures; except that in such spaces above the bulkhead deck, electrical equipment that is enclosed and protected to prevent discharge of sparks may be used if installed more than 450 millimetres above any deck on which vapours may accumulate.
(4) In cargo spaces, other than special category spaces, intended for the carriage of motor vehicles with fuel in their tanks for their propulsion the electrical equipment shall be certified for use in explosive petrol and air mixtures and the cables shall be appropriate for use in such mixtures.
(5) In any ventilation trunk connected to any enclosed space for the carriage of motor vehicles with fuel in their tanks for their propulsion, including a special category space, electrical equipment shall be certified for use in explosive petrol and air mixtures and the cables shall be appropriate for use in such mixtures.
(6) (i) Electrical equipment and cables shall not be installed in enclosed cargo spaces, special category spaces or open ro-ro cargo spaces intended for the carriage of dangerous goods which are flammable liquids with a flash point below 23°C (Closed Cup Test) or flammable gases unless the Secretary of State considers the location therein essential.
(ii)If permitted, any electrical equipment installed in such spaces shall be certified for, and cables shall be appropriate for, use with the flammable dusts, gases or vapours to which it may be exposed.
(iii)Cable penetrations of the decks and bulkheads of such spaces shall be sealed against the passage of gas or vapour.
(iv)Electrical equipment and cables which do not comply with the foregoing for particular applications may be installed, provided such equipment and cables are capable of being electrically isolated by the removal of links or the operation of lockable switches.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.