4.Placing on the market, putting into service and use of instruments
5.Instruments used for Schedule 3 applications to satisfy the essential requirements
6.Information to be borne by instruments not subjected to EC verification, EC unit verification or EC declaration of type conformity
9.Designation of bodies to exercise functions under the Regulations
PART II APPROVAL AND CERTIFICATION OF NON-AUTOMATIC WEIGHING INSTRUMENTS
PART III USE FOR TRADE OF NON-AUTOMATIC WEIGHING INSTRUMENTS
2.2.1.The actual scale interval (d) and the verification scale interval...
2.2.2.For all instruments other than those with auxiliary indicating devices:...
2.2.3.For instruments with auxiliary indicating devices the following conditions apply:...
3.1.Instruments with one weighing range Instruments equipped with an auxiliary...
3.3.1.Instruments with one weighing range may have several partial weighing...
3.3.2.Each partial weighing range i of multi-interval instruments is defined...
3.3.3.The partial ranges are classified according to Table 2. All...
4.1.On implementation of the procedures laid down in Article 8,...
4.2.The maximum permissible errors in service are twice the maximum...
5.Weighing results of an instrument shall be repeatable, and shall...
6.The instrument shall react to small variations in the load....
7.1.Instruments of classes II, III and IIII, liable to be...
7.2.The instruments shall meet the metrological requirements within the temperature...
7.3.Instruments operated from a mains power supply shall meet the...
7.4.Electronic instruments, except those in class I and in class...
7.6.Under other conditions the instruments shall either continue to function...
8.1.Design and construction of the instruments shall be such that...
8.2.When exposed to disturbances, electronic instruments shall not display the...
8.4.When external equipment is connected to an electronic instrument through...
8.5.The instruments shall have no characteristics likely to facilitate fraudulent...
8.6.Instruments shall be designed to permit ready execution of the...
14.Instruments for direct sales to the public with a maximum capacity not greater than 100 kg: additional requirements
APPLICATIONS REFERRED TO IN ARTICLE 1(2)(a)OF THE NAWI DIRECTIVE