13.  The specifications for non-graduated and graduated Class II machines are given in Table 2.E+W+S

Table 2

Maximum capacity “Max”Lower limit of the minimum load “Min”Scale interval “d”Number of scale intervals “n”Verification scale interval “e”

Notes

1.

When a machine is provided with a rider its verification scale interval shall be the smaller of the following—

(a)

the verification scale interval of the machine not taking into account the rider, or

(b)

the scale interval of the rider device.

2.

When graduated self or semi-self indicating machines are provided with a device for interpolation of reading, this shall not be taken into account when determining the verification scale interval of the machine.

3.

When graduated self or semi-self indicating machines are provided with an indicating device on which the last figure is clearly differentiated from the other figures, the verification scale interval shall correspond to the last but one figure of the indication.

4.

Machines of a maximum capacity equal to or greater than 1 kg of an actual scale interval of 100 mg and of a verification scale interval of 1 g may belong to this class of machine, provided that the last figure is clearly differentiated from the other figures.

5.

In the case of machines where the weight indicating or printing is in carat (metric) units or ounces troy the relevant capacity and verification scale interval shall be the amounts in carat (metric) or ounces troy respectively which are equivalent to those specified in the Table in terms of mg, g and kg.

6.

Where the equivalent metric value for an ounce troy scale interval falls between ranges then the value shall be considered as belonging to the lower range.

Non-graduated machines
1 g ≤ Max < 5 g10 e

No math image to display

5 g ≤ Max < 100 g10 e5 mg
100 g ≤ Max < 200 g10 e

No math image to display

200 g ≤ Max50 e

No math image to display

Graduated machines
Non-self indicating machines
1 g ≤ Max < 50 g10 d1 mg ≤ d ≤ 5 mg200 ≤ n < 50 000d
10 g ≤ Max < 50 g50 d10 mg ≤ d ≤ 50 mg1 000 ≤ n < 5 0005 mg
50 g ≤ Max ≤ 500 g10 d1 mg ≤ d ≤ 5 mg10 000 ≤ n ≤ 100 000d
50 g ≤ Max < 5 kg50 d10 mg ≤ d ≤ 500 mg1 000 ≤ n < 10 000

No math image to display

100 g ≤ Max ≤ 50 kg50 d10 mg ≤ d ≤ 500 mg10 000 ≤ n ≤ 100 000d
5 kg ≤ Max50 d1 g ≤ d5 000 ≤ n < 10 000

No math image to display

10 kg ≤ Max50 d1 g ≤ d10 000 ≤ n ≤ 100 000d
Self and semi-self indicating machines
1 g ≤ Max ≤ 500 g10 d1 mg ≤ d ≤ 5 mg200 ≤ n ≤ 100 000d
10 g ≤ Max ≤ 50 kg50 d10 mg ≤ d ≤ 500 mg1 000 ≤ n ≤ 100 000d
5 kg ≤ Max50 d1 g ≤ d5 000 ≤ n ≤ 100 000d