SCHEDULE 1ACCURACY CLASSIFICATION OF NON-AUTOMATIC WEIGHING MACHINES
PART IVMACHINES DESIGNATED CLASS III
I115
The specifications for non-graduated and graduated Class III machines are given in Table 3.
Maximum capacity “Max” | Lower limit of the minimum load “Min” | Scale interval “d” | Number of scale intervals “n” | Verification scale interval “e” |
---|---|---|---|---|
Non-graduated machines | ||||
20 g ≤ Max < 100 g | 20 e | 0.1 g | ||
100 g ≤ Max < 1 kg | 20 e | |||
1 kg ≤ Max < 2 kg | 20 e | 1 g | ||
2 kg ≤ Max | 20 e | |||
Graduated machines | ||||
Non-self indicating machines | ||||
20 g ≤ Max < 100 g | 10 d | 0.1 g ≤ d ≤ 0.2 g | 200 ≤ n < 1 000 | 0.1 g |
100 g ≤ Max < 1 kg | 20 d | 0.2 g ≤ d ≤ 1 g | 200 ≤ n < 1 000 | |
100 g ≤ Max ≤ 10 kg | 20 d | 0.1 g ≤ d ≤ 1 g | 1 000 ≤ n ≤ 10 000 | d |
400 g ≤ Max < 5 kg | 20 d | 2 g ≤ d ≤ 5 g | 200 ≤ n < 1 000 | |
2 kg ≤ Max ≤ 50 kg | 20 d | 2 g ≤ d ≤ 5 g | 1 000 ≤ n ≤ 10 000 | d |
5 kg ≤ Max < 10 t | 20 d | 10 g ≤ d ≤ 10 kg | 500 ≤ n < 1 000 | |
10 kg ≤ Max ≤ 100 t | 20 d | 10 g ≤ d ≤ 10 kg | 1 000 ≤ n ≤ 10 000 | d |
15 t ≤ Max < 100 t | 20 d | 20 kg ≤ d ≤ 50 kg | 750 ≤ n < 1 000 | |
15 t ≤ Max < 100 t | 10 d | 100 kg | 750 ≤ n < 1 000 | |
20 t ≤ Max ≤ 1 000 t | 20 d | 20 kg ≤ d ≤ 50 kg | 1 000 ≤ n ≤ 10 000 | d |
20 t ≤ Max ≤ 1 000 t | 10 d | 100 kg | 1 000 ≤ n ≤ 10 000 | d |
150 t ≤ Max | 10 d | 200 kg ≤ d | 750 ≤ n < 1 000 | |
200 t ≤ Max | 10 d | 200 kg ≤ d | 1 000 ≤ n ≤ 10 000 | d |
Self and semi-self indicating machines | ||||
20 g ≤ Max ≤ 10 kg | 10 d | 0.1 g ≤ d ≤ 1 g | 50 ≤ n ≤ 10 000 | d |
400 g ≤ Max ≤ 50 kg | 20 d | 2 g ≤ d ≤ 5 g | 200 ≤ n ≤ 10 000 | d |
5 kg ≤ Max ≤ 200 kg | 20 d | 10 g ≤ d ≤ 20 g | 500 ≤ n ≤ 10 000 | d |
25 kg ≤ Max ≤ 100 t | 20 d | 50 g ≤ d ≤ 10 kg | 500 ≤ n ≤ 10 000 | d |
15 t ≤ Max ≤ 1 000 t | 20 d | 20 kg ≤ d ≤ 50 kg | 750 ≤ n ≤ 10 000 | d |
15 t ≤ Max ≤ 1 000 t | 10 d | 100 kg | 750 ≤ n ≤ 10 000 | d |
150 t < Max | 10 d | 200 kg ≤ d | 750 ≤ n ≤ 10 000 | d |