The Weighing Equipment (Non-automatic Weighing Machines) Regulations 2000

17.  The specifications for non-graduated and graduated Class IIII machines are given in Table 4.E+W+S

Table 4

Maximum capacity “Max”Lower limit of the minimum load “Min”Scale interval “d”Number of scale intervals “n”Verification scale interval ,“e”
Non-graduated machines
400 g ≤ Max < 2 kg10 e5 g
2 kg ≤ Max10 e

No math image to display

Graduated machines
Non-self indicating machines
400 g ≤ Max < 2 kg10 d5 g ≤ d ≤ 10 g80 ≤ n < 4005 g
2 kg ≤ Max < 4 t10 d10 g ≤ d ≤ 10 kg100 ≤ n < 400

No math image to display

2 kg ≤ Max ≤ 10 t10 d5 g ≤ d ≤ 10 kg400 ≤ n ≤ 1 000d
4 t ≤ Max10 d20 kg ≤ d200 ≤ n < 400

No math image to display

8 t ≤ Max10 d20 kg ≤ d400 ≤ n ≤ 1 000d
Self and semi-self indicating machines
400 g ≤ Max ≤ 10 t10 d2 g ≤ d ≤ 10 kg60 ≤ n ≤ 1 000d
4 t ≤ Max10 d20 kg ≤ d200 ≤ n ≤ 1 000d

Commencement Information