SCHEDULE 2E+W+STESTING

PART IIIE+W+SOTHER TESTING

InterpretationE+W+S

11.  Alternative load balancing arrangement testing

(a)Machines having a weighing mode in which it is possible to obtain more than one determination of a single load by means of alternative load balancing arrangements shall, for each such weighing mode, be tested as described in subparagraphs (b) and (c) below.

(b)If feasible, testing of each alternative load balancing arrangement shall be carried out for at least three different values of test load.

(c)For each test load the inspector shall compare the two readings obtained from the alternative load balancing arrangements. The difference between these readings must not exceed the absolute value (or the smaller of the absolute values) of the appropriate prescribed limits of error for the load applied.

Commencement Information

I1Sch. 2 para. 11 in force at 2.5.2000, see reg. 1(1)