- Latest available (Revised)
- Original (As made)
This is the original version (as it was originally made).
13.—(1) The inspector shall test a beltweigher in accordance with the procedures relating to metrological requirements set out in clauses 5.2.1.1, 5.2.1.2 of, and clause A.11 of Annex A to, R 50–1, and, where appropriate, that relating to the switch-on procedure for electronic beltweighers set out in clause 4.4 of R 50–1.
(2) No beltweigher shall be tested, passed as fit for use for trade and stamped unless either—
(a)it has been completely erected ready for use and installed at the place where it is to be used, or
(b)save in a case where paragraph (3) has effect, it has been completely erected ready for use in conditions which are in all material respects the same as those at the place where it is to be used and it is not to be dismantled before it is installed at that place.
(3) A beltweigher which is to be re-erected at its place of use after testing shall not be passed as fit for use for trade before re-erection in accordance with paragraph (2)(b) if, in the opinion of the inspector, its dismantling, transportation and re-erection are likely to affect its function or accuracy.
(4) Every beltweigher submitted for testing shall be in a clean condition.
(5) For the purposes of the performance by an inspector of his functions under the Act or these Regulations relating to inspection, testing, passing as fit for use for trade and stamping of any beltweigher, a person submitting a beltweigher to an inspector or who an inspector has reasonable cause to believe has possession of a beltweigher for use for trade shall, if requested, provide to the inspector such material, handling equipment and assistance as the inspector may reasonably require; and any material or equipment so provided shall be returned to the person in question.
14.—(1) In relation to a beltweigher imported into Great Britain from another EEA State, subject to paragraph (4), an inspector shall not carry out any test in accordance with regulation 13 if, together with the beltweigher being imported, he is presented with the requisite documentation.
(2) In this regulation and in regulation 15(2)—
(a)“requisite documentation” means—
(i)the test report of an approved body that the beltweigher which is the subject of that report has been tested on the same basis as that set out in this Part of these Regulations or on an equivalent basis and stating which tests have been applied to it; and
(ii)the test results relating to those tests; and
(b)“EEA State” means a State which is a Contracting Party to the EEA Agreement other than the United Kingdom; and in this paragraph “the EEA Agreement” means the Agreement on the European Economic Area signed at Oporto on 2nd May 1992 as adjusted by the Protocol signed at Brussels on 17th March 1993.
(3) A body is an “approved body” for the purposes of paragraph 2 if it is a body in an EEA State which has the responsibility in that State for metrological control of beltweighers or is a laboratory which has been accredited in relation to beltweighers as being a body which conforms with the criteria set out in EN 45001(1) or BS EN ISO 17025:2000(2).
(4) Nothing in these Regulations shall prevent an inspector testing in accordance with regulation 13 where he is not satisfied—
(a)as to the authenticity of the test report or the results presented to him; or
(b)that the test results presented to him are results which in fact relate to the beltweigher being imported; or
(c)either—
(i)that the beltweigher being imported has not been dismantled after the tests to which the test report relates were carried out; or
(ii)where the beltweigher being imported has been dismantled after those tests were carried out, that any such dismantling is not likely to have affected its function or accuracy.
EN 45001 is a European Standard which has the status of a British Standard; it is identical with BS 7501 (ISBN 0 580 17939 7), “General criteria for the operation of testing laboratories”.
BS EN ISO 17025:2000 is the international standard “General requirements for the competence of testing and calibration laboratories” (ISBN 0 580 34929 2).
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: