Search Legislation

The Energy Information (Household Air Conditioners) Regulations 2003

Status:

This is the original version (as it was originally made).

Regulation 7(2)

SCHEDULE 1THE LABEL

Label design

The label shall be in the relevant language version chosen from the following illustrations—

(a)Figure 1, in the case of a cooling only appliance; or

(b)Figure 2, in the case of a cooling/heating appliance;

and shall include the information required by the notes.

Figure 1

Figure 2

2.  The following notes define the information to be included:

I. Supplier’s name or trade mark.

II. Supplier’s model identifier.

For ‘split and multi-split’ units, the model identifier of the indoor and of the outdoor elements of the combination to which the figures quoted below apply.

III. The energy efficiency class of the model, or combination, determined in accordance with Schedule 3.

  • The head of the arrow containing this indicator letter shall be placed at the same level as the head of the relevant arrow.

  • The height of the arrow containing the indicator letter shall not be less than – and not more than twice – the height of the classes arrows.

IV. Without prejudice to any requirements under the Community eco-label scheme, where a model has been granted a ‘European Union eco-label’ under Regulation (EC) No 1980/2000 of the European Parliament and of the Council of 17th July 2000 on a revised Community eco-label award scheme(1) a copy of the eco-label may be added here.

V. The indicative annual energy consumption calculated with the total input power as defined in the harmonised standards multiplied by an average of 500 hours per year in cooling mode at full load, determined in accordance with the test procedures of the harmonised standards (conditions T1 ‘moderate’).

VI. The cooling output defined as the cooling capacity in kW of the appliance in cooling mode at full load, determined in accordance with the test procedures of the harmonised standards (conditions T1 ‘moderate’).

VII. The EER (energy efficiency ratio) of the appliance in cooling mode at full load, determined in accordance with the test procedures of the harmonised standards (conditions T1 ‘moderate’).

VIII. The type of appliance: cooling only, cooling/heating. This indicator arrow shall be placed at the same level as the relevant type.

IX. The cooling mode: air cooled, water cooled.

  • This indicator arrow shall be placed at the same level as the relevant type.

X. Only for appliances with heating capability (Figure 2) the heat output defined as the heating capacity in kW of the appliance in heating mode at full load, determined in accordance with the test procedures of the harmonised standards (conditions T1 +7C).

XI. Only for appliances with heating capability (Figure 2) the heating mode energy efficiency class in accordance with Schedule 3, expressed on a scale of A (higher) to G (lower), determined in accordance with the test procedures of the harmonised standards (conditions T1 +7C). If the appliance heating capability is provided by a resistive element then the COP (coefficient of performance) shall have the value of 1.

XII. Where applicable, noise measured during standard function, determined in accordance with Directive 86/594/EEC(2).

Printing

3.—(1) Figure 3 defines certain aspects of the label.

Figure 3

(2) Colours are to be used on the label in accordance with the following—

  • CMYK - cyan, magenta, yellow, black.

  • Ex: 07X0: 0% cyan, 70% magenta, 100% yellow, 0% black.

  • Arrows

  • A X0X0

  • B 70X0

  • C 30X0

  • D 00X0

  • E 03X0

  • F 07X0

  • G 0XX0

  • Outline: colour X070.

  • The background colour of the energy efficiency class indicator arrow is black.

  • All text is in black. The background is white.

(1)

OJ No. L237, 21.9.2000, p. 1.

(2)

OJ No. L344, 6.12.1986, p. 24; see the Household Appliances (Airborne Noise) Regulations 1990 (S.I 1990/161, amended by S.I. 1994/1386).

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources