There are outstanding changes not yet made by the legislation.gov.uk editorial team to The Energy Information (Household Air Conditioners) Regulations 2003. Any changes that have already been made by the team appear in the content and are referenced with annotations. Help about Changes to Legislation

Regulations 7(2), 8(2) and 12(b)

SCHEDULE 3U.K.ENERGY EFFICIENCY CLASSIFICATION

1.  The energy efficiency class of a regulated household air conditioner shall be determined in accordance with the following tables. The energy efficiency ratio (EER) shall be determined in accordance with the test procedures of the harmonised standards at conditions T1 ‘moderate’.U.K.

(1)U.K.Air-cooled air conditioners

Table 1

(a) split and multi-split appliances

Energy efficiency class Energy efficiency ratio
A3.20 < EER
B3.20 ≥ EER > 3.00
C3.00 ≥ EER > 2.80
D2.80 ≥ EER > 2.60
E2.60 ≥ EER > 2.40
F2.40 ≥ EER > 2.20
G2.20 ≥ EER

(b) packaged ‘double ducts’ units*

Energy efficiency class Energy efficiency ratio
A3.00 < EER
B3.00 ≥ EER > 2.80
C2.80 ≥ EER > 2.60
D2.60 ≥ EER > 2.40
E2.40 ≥ EER > 2.20
F2.20 ≥ EER > 2.00
G2.00 ≥ EER

* Packaged ‘double ducts’ units, defined as ‘Air conditioner completely enclosed inside the conditioned space, with the condenser air intake and discharge connected to the outside by means of two ducts’, will be classified according to Table 1(b) with a correction factor of −0.4.

(c) single duct units

Energy efficiency class Energy efficiency ratio
A2.60 < EER
B2.60 ≥ EER > 2.40
C2.40 ≥ EER > 2.20
D2.20 ≥ EER > 2.00
E2.00 ≥ EER > 1.80
F1.80 ≥ EER > 1.60
G1.60 ≥ EER

(2)U.K. Water-cooled air conditioners

Table 2

(a) split and multi-split appliances

Energy efficiency class Energy efficiency ratio
A3.60 < EER
B3.60 ≥ EER > 3.30
C3.30 ≥ EER > 3.10
D3.10 ≥ EER > 2.80
E2.80 ≥ EER > 2.50
F2.50 ≥ EER > 2.20
G2.20 ≥ EER

(b) packaged appliances

Energy efficiency class Energy efficiency ratio
A4.40 < EER
B4.40 ≥ EER > 4.10
C4.10 ≥ EER > 3.80
D3.80 ≥ EER > 3.50
E3.50 ≥ EER > 3.20
F3.20 ≥ EER > 2.90
G2.90 ≥ EER

2.  The heating mode energy efficiency class shall be determined in accordance with the following Tables, where COP (coefficient of performance) is determined in accordance with the test procedures of the harmonised standards at conditions T1 + 7C.U.K.

(1)U.K.Air-cooled air conditioners – heating mode

Table 3

(a) split and multi-split appliances

Energy efficiency class Coefficient of performance
A3.60 < COP
B3.60 ≥ COP > 3.40
C3.40 ≥ COP > 3.20
D3.20 ≥ COP > 2.80
E2.80 ≥ COP > 2.60
F2.60 ≥ COP > 2.40
G2.40 ≥ COP

(b) Packaged ‘double ducts’ units*

Energy efficiency class Coefficient of performance
A3.40 < COP
B3.40 ≥ COP > 3.20
C3.20 ≥ COP > 3.00
D3.00 ≥ COP > 2.60
E2.60 ≥ COP > 2.40
F2.40 ≥ COP > 2.20
G2.20 ≥ COP

* Packaged ‘double ducts’ units, defined as ‘Air conditioner completely enclosed inside the conditioned space, with the condenser air intake and discharge connected to the outside by means of two ducts’, will be classified according to Table 3(b) with a correction factor of −0.4.

(c) single duct units

Energy efficiency class Coefficient of performance
A3.00 < COP
B3.00 ≥ COP > 2.80
C2.80 ≥ COP > 2.60
D2.60 ≥ COP > 2.40
E2.40 ≥ COP > 2.10
F2.10 ≥ COP > 1.80
G1.80 ≥ COP

(2)U.K.Water-cooled air conditioners - heating mode

Table 4

(a) split and multi-split appliances

Energy efficiency class Coefficient of performance
A4.00 < COP
B4.00 ≥ COP > 3.70
C3.70 ≥ COP > 3.40
D3.40 ≥ COP > 3.10
E3.10 ≥ COP > 2.80
F2.80 ≥ COP > 2.50
G2.50 ≥ COP

(b) packaged appliances

Energy efficiency class Energy efficiency ratio
A4.70 < COP
B4.70 ≥ COP > 4.40
C4.40 ≥ COP > 4.10
D4.10 ≥ COP > 3.80
E3.80 ≥ COP > 3.50
F3.50 ≥ COP > 3.20
G3.20 ≥ COP

Back to top