Regulations 7(2), 8(2) and 12(b)
SCHEDULE 3ENERGY EFFICIENCY CLASSIFICATION
1. The energy efficiency class of a regulated household air conditioner shall be determined in accordance with the following tables. The energy efficiency ratio (EER) shall be determined in accordance with the test procedures of the harmonised standards at conditions T1 ‘moderate’.
(1) Air-cooled air conditioners
Table 1
(a) split and multi-split appliancesEnergy efficiency class | Energy efficiency ratio |
---|
A | 3.20 < EER |
B | 3.20 ≥ EER > 3.00 |
C | 3.00 ≥ EER > 2.80 |
D | 2.80 ≥ EER > 2.60 |
E | 2.60 ≥ EER > 2.40 |
F | 2.40 ≥ EER > 2.20 |
G | 2.20 ≥ EER |
(b) packaged ‘double ducts’ unitsEnergy efficiency class | Energy efficiency ratio |
---|
|
A | 3.00 < EER |
B | 3.00 ≥ EER > 2.80 |
C | 2.80 ≥ EER > 2.60 |
D | 2.60 ≥ EER > 2.40 |
E | 2.40 ≥ EER > 2.20 |
F | 2.20 ≥ EER > 2.00 |
G | 2.00 ≥ EER |
(c) single duct unitsEnergy efficiency class | Energy efficiency ratio |
---|
A | 2.60 < EER |
B | 2.60 ≥ EER > 2.40 |
C | 2.40 ≥ EER > 2.20 |
D | 2.20 ≥ EER > 2.00 |
E | 2.00 ≥ EER > 1.80 |
F | 1.80 ≥ EER > 1.60 |
G | 1.60 ≥ EER |
(2) Water-cooled air conditioners
Table 2
(a) split and multi-split appliancesEnergy efficiency class | Energy efficiency ratio |
---|
A | 3.60 < EER |
B | 3.60 ≥ EER > 3.30 |
C | 3.30 ≥ EER > 3.10 |
D | 3.10 ≥ EER > 2.80 |
E | 2.80 ≥ EER > 2.50 |
F | 2.50 ≥ EER > 2.20 |
G | 2.20 ≥ EER |
(b) packaged appliancesEnergy efficiency class | Energy efficiency ratio |
---|
A | 4.40 < EER |
B | 4.40 ≥ EER > 4.10 |
C | 4.10 ≥ EER > 3.80 |
D | 3.80 ≥ EER > 3.50 |
E | 3.50 ≥ EER > 3.20 |
F | 3.20 ≥ EER > 2.90 |
G | 2.90 ≥ EER |
2. The heating mode energy efficiency class shall be determined in accordance with the following Tables, where COP (coefficient of performance) is determined in accordance with the test procedures of the harmonised standards at conditions T1 + 7C.
(1) Air-cooled air conditioners – heating mode
Table 3
(a) split and multi-split appliancesEnergy efficiency class | Coefficient of performance |
---|
A | 3.60 < COP |
B | 3.60 ≥ COP > 3.40 |
C | 3.40 ≥ COP > 3.20 |
D | 3.20 ≥ COP > 2.80 |
E | 2.80 ≥ COP > 2.60 |
F | 2.60 ≥ COP > 2.40 |
G | 2.40 ≥ COP |
(b) Packaged ‘double ducts’ unitsEnergy efficiency class | Coefficient of performance |
---|
|
A | 3.40 < COP |
B | 3.40 ≥ COP > 3.20 |
C | 3.20 ≥ COP > 3.00 |
D | 3.00 ≥ COP > 2.60 |
E | 2.60 ≥ COP > 2.40 |
F | 2.40 ≥ COP > 2.20 |
G | 2.20 ≥ COP |
(c) single duct unitsEnergy efficiency class | Coefficient of performance |
---|
A | 3.00 < COP |
B | 3.00 ≥ COP > 2.80 |
C | 2.80 ≥ COP > 2.60 |
D | 2.60 ≥ COP > 2.40 |
E | 2.40 ≥ COP > 2.10 |
F | 2.10 ≥ COP > 1.80 |
G | 1.80 ≥ COP |
(2) Water-cooled air conditioners - heating mode
Table 4
(a) split and multi-split appliancesEnergy efficiency class | Coefficient of performance |
---|
A | 4.00 < COP |
B | 4.00 ≥ COP > 3.70 |
C | 3.70 ≥ COP > 3.40 |
D | 3.40 ≥ COP > 3.10 |
E | 3.10 ≥ COP > 2.80 |
F | 2.80 ≥ COP > 2.50 |
G | 2.50 ≥ COP |
(b) packaged appliancesEnergy efficiency class | Energy efficiency ratio |
---|
A | 4.70 < COP |
B | 4.70 ≥ COP > 4.40 |
C | 4.40 ≥ COP > 4.10 |
D | 4.10 ≥ COP > 3.80 |
E | 3.80 ≥ COP > 3.50 |
F | 3.50 ≥ COP > 3.20 |
G | 3.20 ≥ COP |