The Energy Information (Household Air Conditioners) Regulations 2003

Regulations 7(2), 8(2) and 12(b)

SCHEDULE 3ENERGY EFFICIENCY CLASSIFICATION

1.  The energy efficiency class of a regulated household air conditioner shall be determined in accordance with the following tables. The energy efficiency ratio (EER) shall be determined in accordance with the test procedures of the harmonised standards at conditions T1 ‘moderate’.

(1) Air-cooled air conditioners

Table 1

(a) split and multi-split appliances
Energy efficiency classEnergy efficiency ratio
A3.20 < EER
B3.20 ≥ EER > 3.00
C3.00 ≥ EER > 2.80
D2.80 ≥ EER > 2.60
E2.60 ≥ EER > 2.40
F2.40 ≥ EER > 2.20
G2.20 ≥ EER
(b) packaged ‘double ducts’ units*
Energy efficiency classEnergy efficiency ratio
*

Packaged ‘double ducts’ units, defined as ‘Air conditioner completely enclosed inside the conditioned space, with the condenser air intake and discharge connected to the outside by means of two ducts’, will be classified according to Table 1(b) with a correction factor of −0.4.

A3.00 < EER
B3.00 ≥ EER > 2.80
C2.80 ≥ EER > 2.60
D2.60 ≥ EER > 2.40
E2.40 ≥ EER > 2.20
F2.20 ≥ EER > 2.00
G2.00 ≥ EER
(c) single duct units
Energy efficiency classEnergy efficiency ratio
A2.60 < EER
B2.60 ≥ EER > 2.40
C2.40 ≥ EER > 2.20
D2.20 ≥ EER > 2.00
E2.00 ≥ EER > 1.80
F1.80 ≥ EER > 1.60
G1.60 ≥ EER

(2) Water-cooled air conditioners

Table 2

(a) split and multi-split appliances
Energy efficiency classEnergy efficiency ratio
A3.60 < EER
B3.60 ≥ EER > 3.30
C3.30 ≥ EER > 3.10
D3.10 ≥ EER > 2.80
E2.80 ≥ EER > 2.50
F2.50 ≥ EER > 2.20
G2.20 ≥ EER
(b) packaged appliances
Energy efficiency classEnergy efficiency ratio
A4.40 < EER
B4.40 ≥ EER > 4.10
C4.10 ≥ EER > 3.80
D3.80 ≥ EER > 3.50
E3.50 ≥ EER > 3.20
F3.20 ≥ EER > 2.90
G2.90 ≥ EER

2.  The heating mode energy efficiency class shall be determined in accordance with the following Tables, where COP (coefficient of performance) is determined in accordance with the test procedures of the harmonised standards at conditions T1 + 7C.

(1) Air-cooled air conditioners – heating mode

Table 3

(a) split and multi-split appliances
Energy efficiency classCoefficient of performance
A3.60 < COP
B3.60 ≥ COP > 3.40
C3.40 ≥ COP > 3.20
D3.20 ≥ COP > 2.80
E2.80 ≥ COP > 2.60
F2.60 ≥ COP > 2.40
G2.40 ≥ COP
(b) Packaged ‘double ducts’ units*
Energy efficiency classCoefficient of performance
*

Packaged ‘double ducts’ units, defined as ‘Air conditioner completely enclosed inside the conditioned space, with the condenser air intake and discharge connected to the outside by means of two ducts’, will be classified according to Table 3(b) with a correction factor of −0.4.

A3.40 < COP
B3.40 ≥ COP > 3.20
C3.20 ≥ COP > 3.00
D3.00 ≥ COP > 2.60
E2.60 ≥ COP > 2.40
F2.40 ≥ COP > 2.20
G2.20 ≥ COP
(c) single duct units
Energy efficiency classCoefficient of performance
A3.00 < COP
B3.00 ≥ COP > 2.80
C2.80 ≥ COP > 2.60
D2.60 ≥ COP > 2.40
E2.40 ≥ COP > 2.10
F2.10 ≥ COP > 1.80
G1.80 ≥ COP

(2) Water-cooled air conditioners - heating mode

Table 4

(a) split and multi-split appliances
Energy efficiency classCoefficient of performance
A4.00 < COP
B4.00 ≥ COP > 3.70
C3.70 ≥ COP > 3.40
D3.40 ≥ COP > 3.10
E3.10 ≥ COP > 2.80
F2.80 ≥ COP > 2.50
G2.50 ≥ COP
(b) packaged appliances
Energy efficiency classEnergy efficiency ratio
A4.70 < COP
B4.70 ≥ COP > 4.40
C4.40 ≥ COP > 4.10
D4.10 ≥ COP > 3.80
E3.80 ≥ COP > 3.50
F3.50 ≥ COP > 3.20
G3.20 ≥ COP