Regulation 14(d) and (e)

SCHEDULE 5U.K.MAXIMUM PERMISSIBLE ERRORS APPLICABLE TO AN AUTOMATIC CATCHWEIGHER FOR USE FOR TRADE

Table 1

Maximum permissible errors for automatic operation

Net Load (m) in verification scale intervals (e)Maximum permissible errors
Y(I)Y(II)Y(a)Y(b) 
0 < m �?� 50 0000 < m �?� 5 0000 < m �?� 5000 < m �?� 50± 2 e
50 000 < m �?� 200 0005 000 < m �?� 20 000500 < m �?� 200050 < m �?� 200± 3 e
200 000 < m20 000 < m �?� 100 0002 000 < m �?� 10 000200 < m �?� 1 000± 4 e

Table 2

Maximum permissible errors for static weighing in non-automatic operation

Net Load (m) in verification scale intervals (e)Maximum permissible errors
Y(I)Y(II)Y(a)Y(b) 
0 < m �?� 50 0000 < m �?� 5 0000 < m �?� 5000 < m �?� 50± 1 e
50 000 < m �?� 200 0005 000 < m �?� 20 000500 < m �?� 200050 < m �?� 200± 2 e
200 000 < m20 000 < m �?� 100 0002 000 < m �?� 10 000200 < m �?� 1 000± 3 e