SCHEDULE 5MAXIMUM PERMISSIBLE ERRORS APPLICABLE TO AN AUTOMATIC CATCHWEIGHER FOR USE FOR TRADE
Table 1Maximum permissible errors for automatic operation
Net Load (m) in verification scale intervals (e) | Maximum permissible errors | |||
---|---|---|---|---|
Y(I) | Y(II) | Y(a) | Y(b) | |
0 < m ≤ 50 000 | 0 < m ≤ 5 000 | 0 < m ≤ 500 | 0 < m ≤ 50 | ± 2 e |
50 000 < m ≤ 200 000 | 5 000 < m ≤ 20 000 | 500 < m ≤ 2000 | 50 < m ≤ 200 | ± 3 e |
200 000 < m | 20 000 < m ≤ 100 000 | 2 000 < m ≤ 10 000 | 200 < m ≤ 1 000 | ± 4 e |
Table 2Maximum permissible errors for static weighing in non-automatic operation
Net Load (m) in verification scale intervals (e) | Maximum permissible errors | |||
---|---|---|---|---|
Y(I) | Y(II) | Y(a) | Y(b) | |
0 < m ≤ 50 000 | 0 < m ≤ 5 000 | 0 < m ≤ 500 | 0 < m ≤ 50 | ± 1 e |
50 000 < m ≤ 200 000 | 5 000 < m ≤ 20 000 | 500 < m ≤ 2000 | 50 < m ≤ 200 | ± 2 e |
200 000 < m | 20 000 < m ≤ 100 000 | 2 000 < m ≤ 10 000 | 200 < m ≤ 1 000 | ± 3 e |