SCHEDULE 5MAXIMUM PERMISSIBLE ERRORS APPLICABLE TO AN AUTOMATIC CATCHWEIGHER FOR USE FOR TRADE

Regulation 14(d) and (e)

Table 1Maximum permissible errors for automatic operation

Net Load (m) in verification scale intervals (e)

Maximum permissible errors

Y(I)

Y(II)

Y(a)

Y(b)

0 < m ≤ 50 000

0 < m ≤ 5 000

0 < m ≤ 500

0 < m ≤ 50

± 2 e

50 000 < m ≤ 200 000

5 000 < m ≤ 20 000

500 < m ≤ 2000

50 < m ≤ 200

± 3 e

200 000 < m

20 000 < m ≤ 100 000

2 000 < m ≤ 10 000

200 < m ≤ 1 000

± 4 e

Table 2Maximum permissible errors for static weighing in non-automatic operation

Net Load (m) in verification scale intervals (e)

Maximum permissible errors

Y(I)

Y(II)

Y(a)

Y(b)

0 < m ≤ 50 000

0 < m ≤ 5 000

0 < m ≤ 500

0 < m ≤ 50

± 1 e

50 000 < m ≤ 200 000

5 000 < m ≤ 20 000

500 < m ≤ 2000

50 < m ≤ 200

± 2 e

200 000 < m

20 000 < m ≤ 100 000

2 000 < m ≤ 10 000

200 < m ≤ 1 000

± 3 e