Putting into use
41.
Table 6
Accuracy Class | Types of Measuring system |
---|---|
(1) However, Member States may require measuring systems of accuracy class 0.3 or 0.5 when used for the levying of duties on mineral oils when (un)loading ships and rail and road tankers. | |
Note: However, the manufacturer may specify a better accuracy for a certain type of measuring system | |
0.3 | Measuring systems on pipeline |
0.5 | All measuring systems if not differently stated elsewhere in this Table, in particular:
|
1.0 | Measuring system for liquefied gases under pressure measured at a temperature equal to or above -10°C Measuring systems normally in class 0.3 or 0.5 but used for liquids—
|
1.5 | Measuring systems for liquefied carbon dioxide Measuring systems for liquefied gases under pressure measured at a temperature below –10ºC (other than cryogenic liquids) |
2.5 | Measuring systems for cryogenic liquids (temperature below –153ºC) |